2003•Traditional Chinese Drug Research and Clinical PharmacologyRequires access

Content Determination of Paeonol in Liuwei Dihuang Pill by SPE - HPLC

Yuzhu Hu

Open publisher page 0 citations

Abstract

Objective To develop SPE - HPLC method for the assay of paeonol in Liuwei Dihuang Pill (LDP). Methods Separation was performed on a Hypersil ODS(2) column (250 mm×4. 6 mm, 5μm) . The mobile phase consist of methanol - 2 % acetic acid (55 :45, v/v) . The flow rate was 1 mL/min. The UV detection was set at 275 nm. Results Paeonol had a good linear relation in the range of 0. 03998 ~ 0. 7996 ug, the average recovery of honeyed bolus of LDP was 102. 9 % and the RSD was 1.2%; the average recovery of concentrated bolus of LDP was 101. 5 % and the RSD was 1.8%. Conclusion The method is simple, sensitive and rapid and it can be used to determine the paeonol content of LDP.

About this research paper

What this paper is about

Objective To develop SPE - HPLC method for the assay of paeonol in Liuwei Dihuang Pill (LDP). Methods Separation was performed on a Hypersil ODS(2) column (250 mm×4. 6 mm, 5μm) . The mobile phase consist of methanol - 2 % acetic acid (55 :45, v/v) . The flow rate was 1 mL/min. The UV detection was set at 275 nm. Results Paeonol had a good linear relation in the range of 0. 03998 ~ 0. 7996 ug, the average recovery of honeyed bolus of LDP was 102. 9 % and the RSD was 1.2%; the average recovery of concentrated bolus of LDP was 101. 5 % and the RSD was 1.8%. Conclusion The method is simple, sensitive and rapid and it can be used to determine the paeonol content of LDP.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop SPE - HPLC method for the assay of paeonol in Liuwei Dihuang Pill (LDP). Methods Separation was performed on a Hypersil ODS(2) column (250 mm×4. 6 mm, 5μm) . The mobile phase consist of methanol - 2 % acetic acid (55 :45, v/v) . The flow rate was 1 mL/min. The UV detection was set at 275 nm. Results Paeonol had a good linear relation in the range of 0. 03998 ~ 0. 7996 ug, the average recovery of honeyed bolus of LDP was 102. 9 % and the RSD was 1.2%; the average recovery of concentrated bolus of LDP was 101. 5 % and the RSD was 1.8%. Conclusion The method is simple, sensitive and rapid and it can be used to determine the paeonol content of LDP.

Key concepts: Paeonol, Chromatography, High-performance liquid chromatography, Chemistry, Content determination, Bolus (digestion), Acetic acid, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Content Determination of Paeonol in Liuwei Dihuang Pill by SPE - HPLC — Research Paper | ScholarLens