2013•Liaoning Zhongyiyao Daxue xuebaoRequires access

Determination of Tetrahydropalmatine of Yuanhu Zhitong Suppository by HPLC

Ziyang Cheng

Open publisher page 0 citations

Abstract

Objective:To develop a RP-HPLC method for the determination of tetrahydropalmatine in Yuanhu Zhitong suppository.Methods:The separation was performed at 30 ℃ on an Agilent Zorbax 80A Extend-C18 column(150 mm×4.6 mm,5 μm)with a mobile phase of methanol-water-triethylamine(55∶45∶0.1).The flow rate was 1.0 mL·min-1,and the detecting wavelength was 280 nm.Results:The linear range of tetrahydropalmatine was from 19.5 to 97.5 μg·mL-1,the average recovery(n=6)of tetrahydropalmatine was 100.6%(RSD=1.07%).Conclusion:The method is simple and accurate with good reproducibility.It can be used to control the quality of Yuanhu Zhitong suppository.

About this research paper

What this paper is about

Objective:To develop a RP-HPLC method for the determination of tetrahydropalmatine in Yuanhu Zhitong suppository.Methods:The separation was performed at 30 ℃ on an Agilent Zorbax 80A Extend-C18 column(150 mm×4.6 mm,5 μm)with a mobile phase of methanol-water-triethylamine(55∶45∶0.1).The flow rate was 1.0 mL·min-1,and the detecting wavelength was 280 nm.Results:The linear range of tetrahydropalmatine was from 19.5 to 97.5 μg·mL-1,the average recovery(n=6)of tetrahydropalmatine was 100.6%(RSD=1.07%).Conclusion:The method is simple and accurate with good reproducibility.It can be used to control the quality of Yuanhu Zhitong suppository.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To develop a RP-HPLC method for the determination of tetrahydropalmatine in Yuanhu Zhitong suppository.Methods:The separation was performed at 30 ℃ on an Agilent Zorbax 80A Extend-C18 column(150 mm×4.6 mm,5 μm)with a mobile phase of methanol-water-triethylamine(55∶45∶0.1).The flow rate was 1.0 mL·min-1,and the detecting wavelength was 280 nm.Results:The linear range of tetrahydropalmatine was from 19.5 to 97.5 μg·mL-1,the average recovery(n=6)of tetrahydropalmatine was 100.6%(RSD=1.07%).Conclusion:The method is simple and accurate with good reproducibility.It can be used to control the quality of Yuanhu Zhitong suppository.

Key concepts: Tetrahydropalmatine, Suppository, Medicine, Chromatography, Triethylamine, High-performance liquid chromatography, Reproducibility, Content determination

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Tetrahydropalmatine of Yuanhu Zhitong Suppository by HPLC — Research Paper | ScholarLens