2010Anhui Medical and Pharmaceutical JournalRequires access

A rapid and nondestructive method for determinating vitamin B2 tablets by near-infrared diffuse reflectance spectroscopy with fiber-optical probe

Zhen Jie Feng

Open publisher page 0 citations

Abstract

Aim To apply near infrared diffuse reflectance spectrophotometry(NIRDRS) and chemometrics for the quantitative analysis of Vitamin B2 tablets.Method Near-infrared spectra(NIR) in the range of 12 000~4 000 cm-1 were recorded by a fibre optic probe for the Vitamin B2 tablets containing riboflavin in the content of 57.5~87.5 mg·g-1.Different spectra pretreatments methods were compared.Finally,NIR spectra in the wavelength range of 7 116.4~4 468.5 cm-1 were selected to set up the calibration curve by the Partial Least squares Regression(PLSR) method,pre-treating with the first derivative combining multiplicative signal correction(MSC) method.Results The relation coefficients R2 was 0.9378 as indicated from the cross-validation,and the root mean square error of cross-validation(RMSECV) was 1.79,the root mean square error of prediction(RMSEP) 1.36.Conclusion The proposed method is robust,and could be used in the fast analysis of Vitamin B2 tablets.

About this research paper

What this paper is about

Aim To apply near infrared diffuse reflectance spectrophotometry(NIRDRS) and chemometrics for the quantitative analysis of Vitamin B2 tablets.Method Near-infrared spectra(NIR) in the range of 12 000~4 000 cm-1 were recorded by a fibre optic probe for the Vitamin B2 tablets containing riboflavin in the content of 57.5~87.5 mg·g-1.Different spectra pretreatments methods were compared.Finally,NIR spectra in the wavelength range of 7 116.4~4 468.5 cm-1 were selected to set up the calibration curve by the Partial Least squares Regression(PLSR) method,pre-treating with the first derivative combining multiplicative signal correction(MSC) method.Results The relation coefficients R2 was 0.9378 as indicated from the cross-validation,and the root mean square error of cross-validation(RMSECV) was 1.79,the root mean square error of prediction(RMSEP) 1.36.Conclusion The proposed method is robust,and could be used in the fast analysis of Vitamin B2 tablets.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aim To apply near infrared diffuse reflectance spectrophotometry(NIRDRS) and chemometrics for the quantitative analysis of Vitamin B2 tablets.Method Near-infrared spectra(NIR) in the range of 12 000~4 000 cm-1 were recorded by a fibre optic probe for the Vitamin B2 tablets containing riboflavin in the content of 57.5~87.5 mg·g-1.Different spectra pretreatments methods were compared.Finally,NIR spectra in the wavelength range of 7 116.4~4 468.5 cm-1 were selected to set up the calibration curve by the Partial Least squares Regression(PLSR) method,pre-treating with the first derivative combining multiplicative signal correction(MSC) method.Results The relation coefficients R2 was 0.9378 as indicated from the cross-validation,and the root mean square error of cross-validation(RMSECV) was 1.79,the root mean square error of prediction(RMSEP) 1.36.Conclusion The proposed method is robust,and could be used in the fast analysis of Vitamin B2 tablets.

Key concepts: Partial least squares regression, Chemometrics, Diffuse reflection, Diffuse reflectance infrared fourier transform, Near-infrared spectroscopy, Analytical Chemistry (journal), Calibration, Mean squared error

Related papers

Back to paper searchBrowse research topicsOriginal source
A rapid and nondestructive method for determinating vitamin B2 tablets by near-infrared diffuse reflectance spectroscopy with fiber-optical probe — Research Paper | ScholarLens