2010Nursing Journal of Chinese People's Liberation ArmyRequires access

Effects of Upper Arm Placement of Peripherally Inserted Central Catheters with SiteRite5 Vascular Ultrasound Guidance System and Microintroducer Technique

Liang Xue-jiao

Open publisher page 0 citations

Abstract

Objective To observe the effects of peripherally inserted central catheters(PICC) puncture by using SiteRite5 vascular ultrasound guidance system and microintroducer technique.Methods A total of 139 PICC patients from January to November,2009 were divided into the observational group(N=72) and control group(N=67) based on admission sequence.The status of target vessels of the observational group were evaluated with Bard SiteRite5 vascular ultrasound guidance system and then microintroducer technique was used in PICC puncture of the upper arm.The patients of the control group were treated with PICC puncture using normal vascular ultrasound machine.The differences in the one-time success rate and the overall success rate of the puncture,the potential complication and the comfort status were compared between the two groups.Results The one-time success rate and the total success rate reached 97.2% and 100% respectively.After the operation,none of the cases was found with mechanical phlebitis,deep vein thrombosis or local infection.The difference had statistical significance between two groups after therapy(P0.01).Significant difference in PICC puncture pain was observed in the patients of the two groups(P0.01).Conclusion The PICC puncture using SiteRite5 vascular ultrasound guidance system and microintroducer techniques can provide a safe minimal invasive surgery with higher one-time success puncturing rate,lower rate of complications and fewer pains,which has wider clinical applications.

About this research paper

What this paper is about

Objective To observe the effects of peripherally inserted central catheters(PICC) puncture by using SiteRite5 vascular ultrasound guidance system and microintroducer technique.Methods A total of 139 PICC patients from January to November,2009 were divided into the observational group(N=72) and control group(N=67) based on admission sequence.The status of target vessels of the observational group were evaluated with Bard SiteRite5 vascular ultrasound guidance system and then microintroducer technique was used in PICC puncture of the upper arm.The patients of the control group were treated with PICC puncture using normal vascular ultrasound machine.The differences in the one-time success rate and the overall success rate of the puncture,the potential complication and the comfort status were compared between the two groups.Results The one-time success rate and the total success rate reached 97.2% and 100% respectively.After the operation,none of the cases was found with mechanical phlebitis,deep vein thrombosis or local infection.The difference had statistical significance between two groups after therapy(P0.01).Significant difference in PICC puncture pain was observed in the patients of the two groups(P0.01).Conclusion The PICC puncture using SiteRite5 vascular ultrasound guidance system and microintroducer techniques can provide a safe minimal invasive surgery with higher one-time success puncturing rate,lower rate of complications and fewer pains,which has wider clinical applications.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To observe the effects of peripherally inserted central catheters(PICC) puncture by using SiteRite5 vascular ultrasound guidance system and microintroducer technique.Methods A total of 139 PICC patients from January to November,2009 were divided into the observational group(N=72) and control group(N=67) based on admission sequence.The status of target vessels of the observational group were evaluated with Bard SiteRite5 vascular ultrasound guidance system and then microintroducer technique was used in PICC puncture of the upper arm.The patients of the control group were treated with PICC puncture using normal vascular ultrasound machine.The differences in the one-time success rate and the overall success rate of the puncture,the potential complication and the comfort status were compared between the two groups.Results The one-time success rate and the total success rate reached 97.2% and 100% respectively.After the operation,none of the cases was found with mechanical phlebitis,deep vein thrombosis or local infection.The difference had statistical significance between two groups after therapy(P0.01).Significant difference in PICC puncture pain was observed in the patients of the two groups(P0.01).Conclusion The PICC puncture using SiteRite5 vascular ultrasound guidance system and microintroducer techniques can provide a safe minimal invasive surgery with higher one-time success puncturing rate,lower rate of complications and fewer pains,which has wider clinical applications.

Key concepts: Medicine, Ultrasound, Peripherally inserted central catheter, Surgery, Thrombosis, Observational study, Puncturing, Ultrasonography

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of Upper Arm Placement of Peripherally Inserted Central Catheters with SiteRite5 Vascular Ultrasound Guidance System and Microintroducer Technique — Research Paper | ScholarLens