2011•Chinese Journal of Spectroscopy LaboratoryRequires access

Determination of Domperidone in Human Plasma by HPLC-MS/MS

Ya Hong Luo

Open publisher page 0 citations

Abstract

The concentration of domperidone in human plasma was determined by HPLC-MS/MS.The samples were separated by Luna C18 column(150mm×2mm,5μm).The mobile phase was consisted of methanol∶water(0.4% ammonium acetate)(85∶15,V/V).The detection was performed in SRM.There was a good linear relationship for domperidone concentration in the range of 0.5—100ng/mL,and the standard deviation of inter-day,intra-day and accuracy were all less than 10%.This method is sensitive,accurate and fast,which is used for the determination of domperidone in human plasma.

About this research paper

What this paper is about

The concentration of domperidone in human plasma was determined by HPLC-MS/MS.The samples were separated by Luna C18 column(150mm×2mm,5μm).The mobile phase was consisted of methanol∶water(0.4% ammonium acetate)(85∶15,V/V).The detection was performed in SRM.There was a good linear relationship for domperidone concentration in the range of 0.5—100ng/mL,and the standard deviation of inter-day,intra-day and accuracy were all less than 10%.This method is sensitive,accurate and fast,which is used for the determination of domperidone in human plasma.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The concentration of domperidone in human plasma was determined by HPLC-MS/MS.The samples were separated by Luna C18 column(150mm×2mm,5μm).The mobile phase was consisted of methanol∶water(0.4% ammonium acetate)(85∶15,V/V).The detection was performed in SRM.There was a good linear relationship for domperidone concentration in the range of 0.5—100ng/mL,and the standard deviation of inter-day,intra-day and accuracy were all less than 10%.This method is sensitive,accurate and fast,which is used for the determination of domperidone in human plasma.

Key concepts: Domperidone, Chromatography, Human plasma, Chemistry, Ammonium acetate, High-performance liquid chromatography, Relative standard deviation, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Domperidone in Human Plasma by HPLC-MS/MS — Research Paper | ScholarLens