2005•Anhui Medical and Pharmaceutical JournalRequires access

Adetermination of oleanolic acid in material and oleanolic acid troches by HPLC-PAD

Zou Sheng-qin

Open publisher page 0 citations

Abstract

Aim Adetermination method of oleanolic acid in material and oleanolic acid troches by reversed-phase high performance liquid chromtograph was established and at the time the purity of oleanolic acid was derected by means of PhotodiodeArray Detector.MethodsThe chromatographic column,Nova-Pak C_1_8(3.9 150 mm,4 μm),ethanenitrile-water(65∶35,V/V) mobile phase with 0.8 ml·min~-~1 flow rate,the detected wavelength(210 nm),and the column temperature(25℃) were adopted.Result The calibration curve of oleanolic acid was linear under the content of 3.48~17.40 μg,the correlation coefficient was over 0.9999,the detected limlt was 0.3 mg·L~-~1(3σ).The average recovery of oleanolic acid was 99.5 %.ConclusionThe method is simple,accurate and has wider linear range.The method can be adapted to evaluate the quality of medicine that contain oleanolic acid.

About this research paper

What this paper is about

Aim Adetermination method of oleanolic acid in material and oleanolic acid troches by reversed-phase high performance liquid chromtograph was established and at the time the purity of oleanolic acid was derected by means of PhotodiodeArray Detector.MethodsThe chromatographic column,Nova-Pak C_1_8(3.9 150 mm,4 μm),ethanenitrile-water(65∶35,V/V) mobile phase with 0.8 ml·min~-~1 flow rate,the detected wavelength(210 nm),and the column temperature(25℃) were adopted.Result The calibration curve of oleanolic acid was linear under the content of 3.48~17.40 μg,the correlation coefficient was over 0.9999,the detected limlt was 0.3 mg·L~-~1(3σ).The average recovery of oleanolic acid was 99.5 %.ConclusionThe method is simple,accurate and has wider linear range.The method can be adapted to evaluate the quality of medicine that contain oleanolic acid.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aim Adetermination method of oleanolic acid in material and oleanolic acid troches by reversed-phase high performance liquid chromtograph was established and at the time the purity of oleanolic acid was derected by means of PhotodiodeArray Detector.MethodsThe chromatographic column,Nova-Pak C_1_8(3.9 150 mm,4 μm),ethanenitrile-water(65∶35,V/V) mobile phase with 0.8 ml·min~-~1 flow rate,the detected wavelength(210 nm),and the column temperature(25℃) were adopted.Result The calibration curve of oleanolic acid was linear under the content of 3.48~17.40 μg,the correlation coefficient was over 0.9999,the detected limlt was 0.3 mg·L~-~1(3σ).The average recovery of oleanolic acid was 99.5 %.ConclusionThe method is simple,accurate and has wider linear range.The method can be adapted to evaluate the quality of medicine that contain oleanolic acid.

Key concepts: Oleanolic acid, Chromatography, Calibration curve, High-performance liquid chromatography, Chemistry, Content determination, Correlation coefficient, Linear relationship

Related papers

Back to paper searchBrowse research topicsOriginal source
Adetermination of oleanolic acid in material and oleanolic acid troches by HPLC-PAD — Research Paper | ScholarLens