2006Zhonghua jianyan yixue zazhiRequires access

Determination of creatinine in human serum and urine by reversed-phase high pressure liquid chromatography

XU Guo-bi

Open publisher page 0 citations

Abstract

Objective To evaluate the analytical variables of the reversed-phase high pressure liquid chromatography (HPLC) with 5-Fluorouracil(5-Fu) as an internal standard for determining creatinine in human serum and urine. The method was used as a candidate reference method for accuracy assessment of routine creatinine test kits.Methods We tested the accuracy, precision, linearity of the reversed-phase HPLC.We analyzed split samples of a panel of 85 patients’ serum and 94 patients’ urine and compared the results of the routine test kits and HPLC by means of bias plots (percentage differences of results) and standard linear regression.Results The linear range of HPLC method was up to 2 210 μmol/L, the within-run CV(n=5) was below 2.5% and the between-day CV(n=10) was less than 4.5%. The analytical recovery rate was 96.3%~102.4%. All of the test kits correlated very well with HPLC.Conclusions We recommend the reversed-phase HPLC with 5-Fu as an internal standard as a candidate reference method for determining creatinine in human serum and urine.The enzymatic method with creatininase coupled sarcosine oxidase is suitable for routine work in clinical laboratories.

About this research paper

What this paper is about

Objective To evaluate the analytical variables of the reversed-phase high pressure liquid chromatography (HPLC) with 5-Fluorouracil(5-Fu) as an internal standard for determining creatinine in human serum and urine. The method was used as a candidate reference method for accuracy assessment of routine creatinine test kits.Methods We tested the accuracy, precision, linearity of the reversed-phase HPLC.We analyzed split samples of a panel of 85 patients’ serum and 94 patients’ urine and compared the results of the routine test kits and HPLC by means of bias plots (percentage differences of results) and standard linear regression.Results The linear range of HPLC method was up to 2 210 μmol/L, the within-run CV(n=5) was below 2.5% and the between-day CV(n=10) was less than 4.5%. The analytical recovery rate was 96.3%~102.4%. All of the test kits correlated very well with HPLC.Conclusions We recommend the reversed-phase HPLC with 5-Fu as an internal standard as a candidate reference method for determining creatinine in human serum and urine.The enzymatic method with creatininase coupled sarcosine oxidase is suitable for routine work in clinical laboratories.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the analytical variables of the reversed-phase high pressure liquid chromatography (HPLC) with 5-Fluorouracil(5-Fu) as an internal standard for determining creatinine in human serum and urine. The method was used as a candidate reference method for accuracy assessment of routine creatinine test kits.Methods We tested the accuracy, precision, linearity of the reversed-phase HPLC.We analyzed split samples of a panel of 85 patients’ serum and 94 patients’ urine and compared the results of the routine test kits and HPLC by means of bias plots (percentage differences of results) and standard linear regression.Results The linear range of HPLC method was up to 2 210 μmol/L, the within-run CV(n=5) was below 2.5% and the between-day CV(n=10) was less than 4.5%. The analytical recovery rate was 96.3%~102.4%. All of the test kits correlated very well with HPLC.Conclusions We recommend the reversed-phase HPLC with 5-Fu as an internal standard as a candidate reference method for determining creatinine in human serum and urine.The enzymatic method with creatininase coupled sarcosine oxidase is suitable for routine work in clinical laboratories.

Key concepts: High-performance liquid chromatography, Chromatography, Urine, Creatinine, Chemistry, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of creatinine in human serum and urine by reversed-phase high pressure liquid chromatography — Research Paper | ScholarLens