Evaluation of Image Quality and Radiation Dose for Low-tube Voltage Head and Neck CTA
Bao Li-we
Abstract
Bao Li-we
Abstract
Objective: The purpose of this prospective study was to compare with image quality and radiation dose between low voltage and conventional head and neck CTA protocols. Methods: 40 consecutive patients were prospectively enrolled From September 2013 to July 2013, and satisfy the following conditions. Patients in group A was with low tube voltage settings, patients in group B was with traditional tube voltage settings. Two groups were evaluated for image quality, mean attenuation, noise, signal-to-noise ratio(SNR) and contrast-to-noise(CNR) in carotid artery and radiation dose. A P value below 0.05 was considered to be statistically significant. Results: The mean attenuation, noise, SNR and CNR was no statistically significant for group A versus group B(P 0.05). The percentage of assessable coronary artery segments was no statistically significant for group B versus group A(χ2= 1.013, P = 0.314). The mean effective dose was statistically significant for the group A was 2.29 m Sv versus 6.69 m Sv for the group B(t =-59.756, P = 0.000). Conclusion Low tube voltage for head and neck CTA technique could offer assessable image quality and substantially reduced effective radiation dose.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: The purpose of this prospective study was to compare with image quality and radiation dose between low voltage and conventional head and neck CTA protocols. Methods: 40 consecutive patients were prospectively enrolled From September 2013 to July 2013, and satisfy the following conditions. Patients in group A was with low tube voltage settings, patients in group B was with traditional tube voltage settings. Two groups were evaluated for image quality, mean attenuation, noise, signal-to-noise ratio(SNR) and contrast-to-noise(CNR) in carotid artery and radiation dose. A P value below 0.05 was considered to be statistically significant. Results: The mean attenuation, noise, SNR and CNR was no statistically significant for group A versus group B(P 0.05). The percentage of assessable coronary artery segments was no statistically significant for group B versus group A(χ2= 1.013, P = 0.314). The mean effective dose was statistically significant for the group A was 2.29 m Sv versus 6.69 m Sv for the group B(t =-59.756, P = 0.000). Conclusion Low tube voltage for head and neck CTA technique could offer assessable image quality and substantially reduced effective radiation dose.
Key concepts: Medicine, Image quality, Nuclear medicine, Effective dose (radiation), Image noise, Head and neck, Prospective cohort study, Radiation dose