2015Computerized Tomography Theory and ApplicationsRequires access

Evaluation of Image Quality and Radiation Dose for Low-tube Voltage Head and Neck CTA

Bao Li-we

Open publisher page 0 citations

Abstract

Objective: The purpose of this prospective study was to compare with image quality and radiation dose between low voltage and conventional head and neck CTA protocols. Methods: 40 consecutive patients were prospectively enrolled From September 2013 to July 2013, and satisfy the following conditions. Patients in group A was with low tube voltage settings, patients in group B was with traditional tube voltage settings. Two groups were evaluated for image quality, mean attenuation, noise, signal-to-noise ratio(SNR) and contrast-to-noise(CNR) in carotid artery and radiation dose. A P value below 0.05 was considered to be statistically significant. Results: The mean attenuation, noise, SNR and CNR was no statistically significant for group A versus group B(P 0.05). The percentage of assessable coronary artery segments was no statistically significant for group B versus group A(χ2= 1.013, P = 0.314). The mean effective dose was statistically significant for the group A was 2.29 m Sv versus 6.69 m Sv for the group B(t =-59.756, P = 0.000). Conclusion Low tube voltage for head and neck CTA technique could offer assessable image quality and substantially reduced effective radiation dose.

About this research paper

What this paper is about

Objective: The purpose of this prospective study was to compare with image quality and radiation dose between low voltage and conventional head and neck CTA protocols. Methods: 40 consecutive patients were prospectively enrolled From September 2013 to July 2013, and satisfy the following conditions. Patients in group A was with low tube voltage settings, patients in group B was with traditional tube voltage settings. Two groups were evaluated for image quality, mean attenuation, noise, signal-to-noise ratio(SNR) and contrast-to-noise(CNR) in carotid artery and radiation dose. A P value below 0.05 was considered to be statistically significant. Results: The mean attenuation, noise, SNR and CNR was no statistically significant for group A versus group B(P 0.05). The percentage of assessable coronary artery segments was no statistically significant for group B versus group A(χ2= 1.013, P = 0.314). The mean effective dose was statistically significant for the group A was 2.29 m Sv versus 6.69 m Sv for the group B(t =-59.756, P = 0.000). Conclusion Low tube voltage for head and neck CTA technique could offer assessable image quality and substantially reduced effective radiation dose.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: The purpose of this prospective study was to compare with image quality and radiation dose between low voltage and conventional head and neck CTA protocols. Methods: 40 consecutive patients were prospectively enrolled From September 2013 to July 2013, and satisfy the following conditions. Patients in group A was with low tube voltage settings, patients in group B was with traditional tube voltage settings. Two groups were evaluated for image quality, mean attenuation, noise, signal-to-noise ratio(SNR) and contrast-to-noise(CNR) in carotid artery and radiation dose. A P value below 0.05 was considered to be statistically significant. Results: The mean attenuation, noise, SNR and CNR was no statistically significant for group A versus group B(P 0.05). The percentage of assessable coronary artery segments was no statistically significant for group B versus group A(χ2= 1.013, P = 0.314). The mean effective dose was statistically significant for the group A was 2.29 m Sv versus 6.69 m Sv for the group B(t =-59.756, P = 0.000). Conclusion Low tube voltage for head and neck CTA technique could offer assessable image quality and substantially reduced effective radiation dose.

Key concepts: Medicine, Image quality, Nuclear medicine, Effective dose (radiation), Image noise, Head and neck, Prospective cohort study, Radiation dose

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of Image Quality and Radiation Dose for Low-tube Voltage Head and Neck CTA — Research Paper | ScholarLens