2013Zhongguo yixue yingxiangxue zazhiRequires access

Influence of CT Low Tube Voltage on Image Quality and Radiation Dose in Patients with Chest Pain

Mi Wang

Open publisher page 0 citations

Abstract

Purpose To explore the influence of low tube voltage of 128-slice CT on image quality and radiation dose in patients with acute chest pain. Materials and Methods Fifty patients with clinical acute chest pain underwent retrospective ECG-gated TRO on a 128-slice CT scanner. All the patients were randomly divided into group A(100kV) and group B(120 kV), with 25 cases in each group. Image quality was scored by5-point method. CT value, image noise(N), enhanced signal to noise ratio(SNR), contrast to noise ratio(CNR) of aorta, pulmonary and coronary of two groups were measured and calculated. Dose length product(DLP) was recorded and radiation dose(ED) was calculated. The image quality and radiation dose of the two groups were comapred. Results Subjective score of image quality had no statistical signifcance between the two groups(t=- 0.667, P0.05). Average CT value of aorta, pulmonary artery and coronary artery of group A was higher than that of group B, the difference was statistically significant(t=3.753, 2.081, 3.755, P0.05). N, SNR and CNR had no statistically difference between the two groups(t=0.654, 0.818, 1.357, P0.05). ED of group A [(7.25±1.53) mSv] was signifcantly lower than that of group B [(11.86±2.22) mSv](P0.05). Conclusion Low tube voltage 128-slice CT TRO can reduce radiation dose without reducing image quality,which should be widely applied.

About this research paper

What this paper is about

Purpose To explore the influence of low tube voltage of 128-slice CT on image quality and radiation dose in patients with acute chest pain. Materials and Methods Fifty patients with clinical acute chest pain underwent retrospective ECG-gated TRO on a 128-slice CT scanner. All the patients were randomly divided into group A(100kV) and group B(120 kV), with 25 cases in each group. Image quality was scored by5-point method. CT value, image noise(N), enhanced signal to noise ratio(SNR), contrast to noise ratio(CNR) of aorta, pulmonary and coronary of two groups were measured and calculated. Dose length product(DLP) was recorded and radiation dose(ED) was calculated. The image quality and radiation dose of the two groups were comapred. Results Subjective score of image quality had no statistical signifcance between the two groups(t=- 0.667, P0.05). Average CT value of aorta, pulmonary artery and coronary artery of group A was higher than that of group B, the difference was statistically significant(t=3.753, 2.081, 3.755, P0.05). N, SNR and CNR had no statistically difference between the two groups(t=0.654, 0.818, 1.357, P0.05). ED of group A [(7.25±1.53) mSv] was signifcantly lower than that of group B [(11.86±2.22) mSv](P0.05). Conclusion Low tube voltage 128-slice CT TRO can reduce radiation dose without reducing image quality,which should be widely applied.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Purpose To explore the influence of low tube voltage of 128-slice CT on image quality and radiation dose in patients with acute chest pain. Materials and Methods Fifty patients with clinical acute chest pain underwent retrospective ECG-gated TRO on a 128-slice CT scanner. All the patients were randomly divided into group A(100kV) and group B(120 kV), with 25 cases in each group. Image quality was scored by5-point method. CT value, image noise(N), enhanced signal to noise ratio(SNR), contrast to noise ratio(CNR) of aorta, pulmonary and coronary of two groups were measured and calculated. Dose length product(DLP) was recorded and radiation dose(ED) was calculated. The image quality and radiation dose of the two groups were comapred. Results Subjective score of image quality had no statistical signifcance between the two groups(t=- 0.667, P0.05). Average CT value of aorta, pulmonary artery and coronary artery of group A was higher than that of group B, the difference was statistically significant(t=3.753, 2.081, 3.755, P0.05). N, SNR and CNR had no statistically difference between the two groups(t=0.654, 0.818, 1.357, P0.05). ED of group A [(7.25±1.53) mSv] was signifcantly lower than that of group B [(11.86±2.22) mSv](P0.05). Conclusion Low tube voltage 128-slice CT TRO can reduce radiation dose without reducing image quality,which should be widely applied.

Key concepts: Medicine, Image quality, Image noise, Nuclear medicine, Radiation dose, Effective dose (radiation), Radiology, Aorta

Related papers

Back to paper searchBrowse research topicsOriginal source
Influence of CT Low Tube Voltage on Image Quality and Radiation Dose in Patients with Chest Pain — Research Paper | ScholarLens