2006Anhui Medical and Pharmaceutical JournalRequires access

Determination of astragaloside IV in astragalus by HPLC-ELSD

Ju-Tao Wang, XU Wen-fang, Jinqi Liu, MA Feng-yu

Open publisher page 0 citations

Abstract

AimTo determine astragaloside Ⅳ in Astragalus by HPLC-ELSD.MethodsHPLC-ELSD was used in the quantitative analysis of astragaloside Ⅳ in the sample.The separation was performed on Hanbang C_(18)(4.6 mm×150 mm,5 μm)column with a mixture of acetonitrile-water(40:60) as mobile phase.The flow rate was 1.0 ml·min~(-1).The temperature of drift tube for measurement was 105℃,and the flow rate of N_(2) was 2.8 L·min~(-1).ResultsThe standard curve was linear in the range of 4.0~18.0 μg for astragaloside Ⅳ(r=0.9999,n=6).The average recovery was 98%.ConclusionThe method is simple,reliable,and is a good method to determine astragaloside Ⅳ.

About this research paper

What this paper is about

AimTo determine astragaloside Ⅳ in Astragalus by HPLC-ELSD.MethodsHPLC-ELSD was used in the quantitative analysis of astragaloside Ⅳ in the sample.The separation was performed on Hanbang C_(18)(4.6 mm×150 mm,5 μm)column with a mixture of acetonitrile-water(40:60) as mobile phase.The flow rate was 1.0 ml·min~(-1).The temperature of drift tube for measurement was 105℃,and the flow rate of N_(2) was 2.8 L·min~(-1).ResultsThe standard curve was linear in the range of 4.0~18.0 μg for astragaloside Ⅳ(r=0.9999,n=6).The average recovery was 98%.ConclusionThe method is simple,reliable,and is a good method to determine astragaloside Ⅳ.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AimTo determine astragaloside Ⅳ in Astragalus by HPLC-ELSD.MethodsHPLC-ELSD was used in the quantitative analysis of astragaloside Ⅳ in the sample.The separation was performed on Hanbang C_(18)(4.6 mm×150 mm,5 μm)column with a mixture of acetonitrile-water(40:60) as mobile phase.The flow rate was 1.0 ml·min~(-1).The temperature of drift tube for measurement was 105℃,and the flow rate of N_(2) was 2.8 L·min~(-1).ResultsThe standard curve was linear in the range of 4.0~18.0 μg for astragaloside Ⅳ(r=0.9999,n=6).The average recovery was 98%.ConclusionThe method is simple,reliable,and is a good method to determine astragaloside Ⅳ.

Key concepts: Astragaloside, Drift tube, Chromatography detector, Chromatography, High-performance liquid chromatography, Astragalus, Chemistry, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of astragaloside IV in astragalus by HPLC-ELSD — Research Paper | ScholarLens