2006RelayRequires access

Measuring method of one-phase grounding capacitive current in 10 kV distribution network

Lijun Chen

Open publisher page 0 citations

Abstract

As for 10 kV distribution network with small neutral point grounding resistor or arc-suppression coil,the key problem is whether the calculation of grounding capacitive current in 10 kV main bus is right.This paper introduces the composition of one-phase grounding capacitive current in weak current grounding system,and points out the calculation method of capacitive current is an effective way for judging if it needs to equip the small grounding resistor or arc-suppression coil in a new project.The different calculation methods of one-phase grounding capacitive current in various condition are analyzed.The real case that comparing the theoretical calculation with practical measurement of capacitive current in 10 kV main bus in 110 kV substation verifies the measuring method is very precise,and it is worthy to be applied widely.

About this research paper

What this paper is about

As for 10 kV distribution network with small neutral point grounding resistor or arc-suppression coil,the key problem is whether the calculation of grounding capacitive current in 10 kV main bus is right.This paper introduces the composition of one-phase grounding capacitive current in weak current grounding system,and points out the calculation method of capacitive current is an effective way for judging if it needs to equip the small grounding resistor or arc-suppression coil in a new project.The different calculation methods of one-phase grounding capacitive current in various condition are analyzed.The real case that comparing the theoretical calculation with practical measurement of capacitive current in 10 kV main bus in 110 kV substation verifies the measuring method is very precise,and it is worthy to be applied widely.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

As for 10 kV distribution network with small neutral point grounding resistor or arc-suppression coil,the key problem is whether the calculation of grounding capacitive current in 10 kV main bus is right.This paper introduces the composition of one-phase grounding capacitive current in weak current grounding system,and points out the calculation method of capacitive current is an effective way for judging if it needs to equip the small grounding resistor or arc-suppression coil in a new project.The different calculation methods of one-phase grounding capacitive current in various condition are analyzed.The real case that comparing the theoretical calculation with practical measurement of capacitive current in 10 kV main bus in 110 kV substation verifies the measuring method is very precise,and it is worthy to be applied widely.

Key concepts: Arc suppression, Ground, Capacitive sensing, Resistor, Electromagnetic coil, Electrical engineering, Earthing system, Current (fluid)

Related papers

Back to paper searchBrowse research topicsOriginal source
Measuring method of one-phase grounding capacitive current in 10 kV distribution network — Research Paper | ScholarLens