Application Principle of Neutral Grounding Method for 66kV System

Dan Zhao, Guanhua Li, Song Yundong, Wang Ting, Chi Danyi

Open publisher page 0 citations

Abstract

In order to optimize the distribution system, selecting the proper neutral point grounding method is one of the most important methods to improve the reliability and economical efficiency of the distribution network. Therefore, the selection and application of the neutral point grounding method is to improve the operation level of the distribution system. The key factor. This paper analyzes and establishes a simulation calculation model to study the single-phase earth fault current and over-voltage characteristics in the arc suppression coil grounding, low-resistance grounding, arc suppression coil, and low-resistance grounding methods of the distribution network neutral point 66kV system. The application principle of neutral point grounding method for 66kV system and the effectiveness and applicability of different capacitive current testing methods are proposed to improve the safety of the urban 66kV system power grid.

About this research paper

What this paper is about

In order to optimize the distribution system, selecting the proper neutral point grounding method is one of the most important methods to improve the reliability and economical efficiency of the distribution network. Therefore, the selection and application of the neutral point grounding method is to improve the operation level of the distribution system. The key factor. This paper analyzes and establishes a simulation calculation model to study the single-phase earth fault current and over-voltage characteristics in the arc suppression coil grounding, low-resistance grounding, arc suppression coil, and low-resistance grounding methods of the distribution network neutral point 66kV system. The application principle of neutral point grounding method for 66kV system and the effectiveness and applicability of different capacitive current testing methods are proposed to improve the safety of the urban 66kV system power grid.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In order to optimize the distribution system, selecting the proper neutral point grounding method is one of the most important methods to improve the reliability and economical efficiency of the distribution network. Therefore, the selection and application of the neutral point grounding method is to improve the operation level of the distribution system. The key factor. This paper analyzes and establishes a simulation calculation model to study the single-phase earth fault current and over-voltage characteristics in the arc suppression coil grounding, low-resistance grounding, arc suppression coil, and low-resistance grounding methods of the distribution network neutral point 66kV system. The application principle of neutral point grounding method for 66kV system and the effectiveness and applicability of different capacitive current testing methods are proposed to improve the safety of the urban 66kV system power grid.

Key concepts: Arc suppression, Ground, Earthing system, Electromagnetic coil, Reliability (semiconductor), Point (geometry), Electric power system, Computer science