Analysis of 10kV grid arc grounding over-voltage hazards and countermeasures

You Hongxia, Yueyue Li, Hai‐Nan Su, Junyi Zhang, Lijun Li, Bai Xue, Runjing Chen

Open publisher page 2 citations

Abstract

Through the analysis of 2 single-phase grounding over voltage accidents caused by capacitive over current in 10 kV power grids in this paper, the causes and damages of arc grounding over voltage are illustrated, and the necessity of capacitive current test and effective methods are pointed out. The test and assessment to the 29 substations' capacitor currents provides a scientific basis for the correct selection of the neutral point operation mode, and the strengths and weaknesses of the neutral Point grounding through the arc suppression circle and the mode trends of 10kV grid neutral grounding are demonstrated.

About this research paper

What this paper is about

Through the analysis of 2 single-phase grounding over voltage accidents caused by capacitive over current in 10 kV power grids in this paper, the causes and damages of arc grounding over voltage are illustrated, and the necessity of capacitive current test and effective methods are pointed out. The test and assessment to the 29 substations' capacitor currents provides a scientific basis for the correct selection of the neutral point operation mode, and the strengths and weaknesses of the neutral Point grounding through the arc suppression circle and the mode trends of 10kV grid neutral grounding are demonstrated.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Through the analysis of 2 single-phase grounding over voltage accidents caused by capacitive over current in 10 kV power grids in this paper, the causes and damages of arc grounding over voltage are illustrated, and the necessity of capacitive current test and effective methods are pointed out. The test and assessment to the 29 substations' capacitor currents provides a scientific basis for the correct selection of the neutral point operation mode, and the strengths and weaknesses of the neutral Point grounding through the arc suppression circle and the mode trends of 10kV grid neutral grounding are demonstrated.

Key concepts: Ground, Arc suppression, Electrical engineering, Capacitive sensing, Voltage, Capacitor, Engineering, Point (geometry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Analysis of 10kV grid arc grounding over-voltage hazards and countermeasures — Research Paper | ScholarLens