2012•Northwest Pharmaceutical JournalRequires access

Determination of residual solvents in tigecycline by headspace capillary GC

Xiangfeng Chen

Open publisher page 0 citations

Abstract

Objective To establish a method of headspace capillary GC for the determination of residual solvents in tigecycline.Methods The GC method was conducted on a PEG-20M capillary column(30 m×0.53 mm,1 μm)with procedural column temperature control.Nitrogen was used as the carrier gas and FID as the detector.Results The four residual solvents(diethyl ether,methanol,dichloromethane,and isopropanol) were completely separated,and the linearities were fairly good(r0.999).The recoveries were 99.4%,99.3%,97.5%,and 98.8%,respectively.The limits of detection were 0.42,0.61,1.53 and 0.65 μg·mL-1,respectively.Conclusion The established method is sensitive and accurate,and can be used for the determination of residual solvents in tigecycline.

About this research paper

What this paper is about

Objective To establish a method of headspace capillary GC for the determination of residual solvents in tigecycline.Methods The GC method was conducted on a PEG-20M capillary column(30 m×0.53 mm,1 μm)with procedural column temperature control.Nitrogen was used as the carrier gas and FID as the detector.Results The four residual solvents(diethyl ether,methanol,dichloromethane,and isopropanol) were completely separated,and the linearities were fairly good(r0.999).The recoveries were 99.4%,99.3%,97.5%,and 98.8%,respectively.The limits of detection were 0.42,0.61,1.53 and 0.65 μg·mL-1,respectively.Conclusion The established method is sensitive and accurate,and can be used for the determination of residual solvents in tigecycline.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method of headspace capillary GC for the determination of residual solvents in tigecycline.Methods The GC method was conducted on a PEG-20M capillary column(30 m×0.53 mm,1 μm)with procedural column temperature control.Nitrogen was used as the carrier gas and FID as the detector.Results The four residual solvents(diethyl ether,methanol,dichloromethane,and isopropanol) were completely separated,and the linearities were fairly good(r0.999).The recoveries were 99.4%,99.3%,97.5%,and 98.8%,respectively.The limits of detection were 0.42,0.61,1.53 and 0.65 μg·mL-1,respectively.Conclusion The established method is sensitive and accurate,and can be used for the determination of residual solvents in tigecycline.

Key concepts: Chromatography, Chemistry, Dichloromethane, Capillary action, Residual, Methanol, Gas chromatography, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of residual solvents in tigecycline by headspace capillary GC — Research Paper | ScholarLens