2010•Marine Environmental ScienceRequires access

Determination of methyl parathion,malathion and parathion in seawater by GC/MS with solid-phase extraction

Yang Jia-huan

Open publisher page 0 citations

Abstract

A method was established for methyl parathion,malathion and parathion in seawater by GC/MS with solid-phase extraction.Methyl parathion,malathion and parathion were extracted from seawater with octadecylsilica(C18) SPE cartridge,eluted with the methylene chloride,detected by selected ion monitoring mode and phenanthrene-d10 as internal standard.The good linear responses were achieved and little inference.The detection limit was 0.20ng/L when the sample volume was 2L and average recoveries 96.0%~122%(n=6),RSD 2.3%~6.8% by the standards were put in seawater.

About this research paper

What this paper is about

A method was established for methyl parathion,malathion and parathion in seawater by GC/MS with solid-phase extraction.Methyl parathion,malathion and parathion were extracted from seawater with octadecylsilica(C18) SPE cartridge,eluted with the methylene chloride,detected by selected ion monitoring mode and phenanthrene-d10 as internal standard.The good linear responses were achieved and little inference.The detection limit was 0.20ng/L when the sample volume was 2L and average recoveries 96.0%~122%(n=6),RSD 2.3%~6.8% by the standards were put in seawater.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method was established for methyl parathion,malathion and parathion in seawater by GC/MS with solid-phase extraction.Methyl parathion,malathion and parathion were extracted from seawater with octadecylsilica(C18) SPE cartridge,eluted with the methylene chloride,detected by selected ion monitoring mode and phenanthrene-d10 as internal standard.The good linear responses were achieved and little inference.The detection limit was 0.20ng/L when the sample volume was 2L and average recoveries 96.0%~122%(n=6),RSD 2.3%~6.8% by the standards were put in seawater.

Key concepts: Parathion, Chromatography, Solid phase extraction, Seawater, Malathion, Chemistry, Parathion methyl, Extraction (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of methyl parathion,malathion and parathion in seawater by GC/MS with solid-phase extraction — Research Paper | ScholarLens