SPE followed by HPLC for the sensitive determination of organic phosphorus pesticides in environmental water
Huaixia Chen
Abstract
Huaixia Chen
Abstract
A solid-phase extraction(SPE) method followed by the high-performance liquid chromatography(HPLC) was established for the determination of organic phosphorus pesticides in environmental water samples.Water samples were filtered twice with 0.22 μm membrane.C18 solid phase extraction was used for the enrichment of organic phosphorus pesticides.The compounds were eluted by acetonitrile.The eluent was analyted by HPLC directly.The experimental results showed that the scope of the work curve of methyl parathion were 2.0-80 μg/L、 fenitrothion 3.0-80 μg/L、 parathion 3.0-100 μg/L、 phoxim 5.0-100 μg/L;the limit of detection(LOD) of methyl parathion,fenitrothion parathion phoxim were 0.11 μg/L、 0.52 μg/L、 0.45 μg/L、 0.85 μg/L,respectively.and recoveries were 84.2% 102.2%.The method is simple,fast,low-cost,high recovery rate and enrichment factor,and so it is suitable to the detection of organic phosphorus residues in environmental water samples.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A solid-phase extraction(SPE) method followed by the high-performance liquid chromatography(HPLC) was established for the determination of organic phosphorus pesticides in environmental water samples.Water samples were filtered twice with 0.22 μm membrane.C18 solid phase extraction was used for the enrichment of organic phosphorus pesticides.The compounds were eluted by acetonitrile.The eluent was analyted by HPLC directly.The experimental results showed that the scope of the work curve of methyl parathion were 2.0-80 μg/L、 fenitrothion 3.0-80 μg/L、 parathion 3.0-100 μg/L、 phoxim 5.0-100 μg/L;the limit of detection(LOD) of methyl parathion,fenitrothion parathion phoxim were 0.11 μg/L、 0.52 μg/L、 0.45 μg/L、 0.85 μg/L,respectively.and recoveries were 84.2% 102.2%.The method is simple,fast,low-cost,high recovery rate and enrichment factor,and so it is suitable to the detection of organic phosphorus residues in environmental water samples.
Key concepts: Chemistry, Chromatography, Solid phase extraction, High-performance liquid chromatography, Phoxim, Extraction (chemistry), Parathion, Pesticide