Experimental study on flat loop heat pipes used in HCPV systems
Minghou Liu
Abstract
Minghou Liu
Abstract
A flat loop heat pipe(FLHP) with a mixed sintered wick was designed for cooling off high concentration photovoltaic(HCPV) solar cells.The effect of heat load,inclination angle and condenser parameters on the start-up and operating performance of the heat pipe was experimentally studied.It was found that the heat pipe can basically meet the needs of HCPV cooling both in heat load and installation angle requirements.The maximum heat load is up to 320 W(40 W/cm2) when the temperature of the heating surface is under 100 ℃.Relative positions between evaporator and accumulator,evaporator and condenser have important influences on the start-up and operating performance of the heat pipe.The pipe may start more easily when the compensation chamber is under the evaporator.The start-up temperature of low heat load drops when the condenser is placed above the evaporator.The capability of anti-gravity start-up performance of the heat pipe can be improved by reducing the flow rate of cooling water in the condenser.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A flat loop heat pipe(FLHP) with a mixed sintered wick was designed for cooling off high concentration photovoltaic(HCPV) solar cells.The effect of heat load,inclination angle and condenser parameters on the start-up and operating performance of the heat pipe was experimentally studied.It was found that the heat pipe can basically meet the needs of HCPV cooling both in heat load and installation angle requirements.The maximum heat load is up to 320 W(40 W/cm2) when the temperature of the heating surface is under 100 ℃.Relative positions between evaporator and accumulator,evaporator and condenser have important influences on the start-up and operating performance of the heat pipe.The pipe may start more easily when the compensation chamber is under the evaporator.The start-up temperature of low heat load drops when the condenser is placed above the evaporator.The capability of anti-gravity start-up performance of the heat pipe can be improved by reducing the flow rate of cooling water in the condenser.
Key concepts: Loop heat pipe, Condenser (optics), Evaporator, Micro-loop heat pipe, Heat pipe, Materials science, Thermosiphon, Mechanics