2012•Huagong jinzhanRequires access

Experimental investigation on the performance of loop heat pipe with flat evaporator

Xianfeng Zhang

Open publisher page 1 citations

Abstract

To investigate the effect of condenser location and gravity on operating performance,a miniature loop heat pipe with series flat evaporator were tested.The results show that the loop heat pipe can start up successfully at various positions under a low heat load(20 W) and have good operating performance with Qmax=130 W and R=0.21 /W.At horizontal ℃ al position,the loop heat pipe with shorter vapor line has better start-up performance and higher Qmax.Under a higher heat load,the effect of condenser location on operating performance becomes more noticeable.It is found that a loop heat pipe with series flat evaporator has good anti-gravity capability and can operate with all elevations and tilts.When the loop heat pipe is at vertical position with compensation chamber above the evaporator,its operating performance is the best under the gravity field.

About this research paper

What this paper is about

To investigate the effect of condenser location and gravity on operating performance,a miniature loop heat pipe with series flat evaporator were tested.The results show that the loop heat pipe can start up successfully at various positions under a low heat load(20 W) and have good operating performance with Qmax=130 W and R=0.21 /W.At horizontal ℃ al position,the loop heat pipe with shorter vapor line has better start-up performance and higher Qmax.Under a higher heat load,the effect of condenser location on operating performance becomes more noticeable.It is found that a loop heat pipe with series flat evaporator has good anti-gravity capability and can operate with all elevations and tilts.When the loop heat pipe is at vertical position with compensation chamber above the evaporator,its operating performance is the best under the gravity field.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To investigate the effect of condenser location and gravity on operating performance,a miniature loop heat pipe with series flat evaporator were tested.The results show that the loop heat pipe can start up successfully at various positions under a low heat load(20 W) and have good operating performance with Qmax=130 W and R=0.21 /W.At horizontal ℃ al position,the loop heat pipe with shorter vapor line has better start-up performance and higher Qmax.Under a higher heat load,the effect of condenser location on operating performance becomes more noticeable.It is found that a loop heat pipe with series flat evaporator has good anti-gravity capability and can operate with all elevations and tilts.When the loop heat pipe is at vertical position with compensation chamber above the evaporator,its operating performance is the best under the gravity field.

Key concepts: Micro-loop heat pipe, Loop heat pipe, Condenser (optics), Evaporator, Heat pipe, Loop (graph theory), Mechanics, Thermal expansion valve

Related papers

Back to paper searchBrowse research topicsOriginal source
Experimental investigation on the performance of loop heat pipe with flat evaporator — Research Paper | ScholarLens