2012•Heat Pipe Science and Technology An International JournalRequires access

INVESTIGATION OF THE OPERATING CHARACTERISTICS OF A LOOP HEAT PIPE AT DIFFERENT CONDENSER COOLING TEMPERATURES

S.I. Yushakova, Sergey V. Vershinin, Yury F. Maydanik

Open publisher page 2 citations

Abstract

The results of developing and investigating the operating characteristics of a copper−water loop heat pipe (LHP) with a heat transfer effective length of 310 mm are presented. The pipe was equipped with a 7 mm thick flat−oval evaporator with a 30 × 30 mm active zone, a condenser with spiral finning, and a cooling jacket. The tests have been conducted at horizontal and vertical orientations of the device in the electric power range from 5 to 1400 W, with water temperature, cooling the LHP condenser, varied in the range from 10 to 80°C. The dependence of parameters, characterizing the LHP operating efficiency, on the condenser cooling temperature has been studied in tests. The research on the start-up of the device at low and moderate heat loads has also been carried out.

About this research paper

What this paper is about

The results of developing and investigating the operating characteristics of a copper−water loop heat pipe (LHP) with a heat transfer effective length of 310 mm are presented. The pipe was equipped with a 7 mm thick flat−oval evaporator with a 30 × 30 mm active zone, a condenser with spiral finning, and a cooling jacket. The tests have been conducted at horizontal and vertical orientations of the device in the electric power range from 5 to 1400 W, with water temperature, cooling the LHP condenser, varied in the range from 10 to 80°C. The dependence of parameters, characterizing the LHP operating efficiency, on the condenser cooling temperature has been studied in tests. The research on the start-up of the device at low and moderate heat loads has also been carried out.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The results of developing and investigating the operating characteristics of a copper−water loop heat pipe (LHP) with a heat transfer effective length of 310 mm are presented. The pipe was equipped with a 7 mm thick flat−oval evaporator with a 30 × 30 mm active zone, a condenser with spiral finning, and a cooling jacket. The tests have been conducted at horizontal and vertical orientations of the device in the electric power range from 5 to 1400 W, with water temperature, cooling the LHP condenser, varied in the range from 10 to 80°C. The dependence of parameters, characterizing the LHP operating efficiency, on the condenser cooling temperature has been studied in tests. The research on the start-up of the device at low and moderate heat loads has also been carried out.

Key concepts: Condenser (optics), Loop heat pipe, Materials science, Water cooling, Evaporator, Heat transfer, Heat pipe, Micro-loop heat pipe

Related papers

Back to paper searchBrowse research topicsOriginal source
INVESTIGATION OF THE OPERATING CHARACTERISTICS OF A LOOP HEAT PIPE AT DIFFERENT CONDENSER COOLING TEMPERATURES — Research Paper | ScholarLens