2004•Engineering MechanicsRequires access

A REVIEW ON THE SEISMIC PERFORMANCE OF STEEL MOMENT CONNECTIONS WITH REDUCED BEAM SECTIONS

RU Ji-ping

Open publisher page 6 citations

Abstract

During the 1994 Northridge earthquake and 1995 Kobe earthquake, the typical beam-column moment connection(bolted-web-welded-flange) in steel moment-resisting frame suffered unexpected brittle failures. A brief review on beam-column connections used in steel moment resisting frame after 1994 Northridge earthquake and 1995 Kobe earthquake is presented in this paper. The development of steel moment connections with reduced-beam sections is addressed. The performance on steel moment connections with reduced-beam sections is analyzed. According to the results of tests and numerical analyses, steel moment connections with reduced-beam sections give a positive influence on the aseismic performance of steel moment resisting frame. It is suggested that by trimming the beam flanges according to the moment profile, the ductility of the connections can be improved and the ductile design on steel frame can be realized.

About this research paper

What this paper is about

During the 1994 Northridge earthquake and 1995 Kobe earthquake, the typical beam-column moment connection(bolted-web-welded-flange) in steel moment-resisting frame suffered unexpected brittle failures. A brief review on beam-column connections used in steel moment resisting frame after 1994 Northridge earthquake and 1995 Kobe earthquake is presented in this paper. The development of steel moment connections with reduced-beam sections is addressed. The performance on steel moment connections with reduced-beam sections is analyzed. According to the results of tests and numerical analyses, steel moment connections with reduced-beam sections give a positive influence on the aseismic performance of steel moment resisting frame. It is suggested that by trimming the beam flanges according to the moment profile, the ductility of the connections can be improved and the ductile design on steel frame can be realized.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

During the 1994 Northridge earthquake and 1995 Kobe earthquake, the typical beam-column moment connection(bolted-web-welded-flange) in steel moment-resisting frame suffered unexpected brittle failures. A brief review on beam-column connections used in steel moment resisting frame after 1994 Northridge earthquake and 1995 Kobe earthquake is presented in this paper. The development of steel moment connections with reduced-beam sections is addressed. The performance on steel moment connections with reduced-beam sections is analyzed. According to the results of tests and numerical analyses, steel moment connections with reduced-beam sections give a positive influence on the aseismic performance of steel moment resisting frame. It is suggested that by trimming the beam flanges according to the moment profile, the ductility of the connections can be improved and the ductile design on steel frame can be realized.

Key concepts: Flange, Structural engineering, Moment (physics), Beam (structure), Ductility (Earth science), Welding, Engineering, Connection (principal bundle)

Related papers

Back to paper searchBrowse research topicsOriginal source
A REVIEW ON THE SEISMIC PERFORMANCE OF STEEL MOMENT CONNECTIONS WITH REDUCED BEAM SECTIONS — Research Paper | ScholarLens