2009•Heilongjiang nongye kexueRequires access

Determination of Isoprothiolane Residues in Aquatic Products by Gas Chromatography

You Qing-shan

Open publisher page 0 citations

Abstract

The gas chromatographic method was used to determine isoprothiolane residues in rice.The isoprothiolane residue in the test sample was extracted with acetonitrile.After the extracts was evaporated,the residues were cleaned up by solid phase extraction(SPE)with a neutral aluminum oxide cartridge and a florisil cartridge.The residue was determined by GC with ECD-detector,using external standard method.The liner range was 0.002 5~0.250 0 μg·mL-1 for isoprothiolane.The correlation coefficients were 0.9996 for isoprothiolane.The regression equation was y= 57194.11x-71.82.The average recoveries of isoprothiolane in spiked samples ranged from 87.8%~106.7%,and the relative standard deviations were between 4.35%~9.91%.The limit of detection was 0.005 mg·kg-1 in method.

About this research paper

What this paper is about

The gas chromatographic method was used to determine isoprothiolane residues in rice.The isoprothiolane residue in the test sample was extracted with acetonitrile.After the extracts was evaporated,the residues were cleaned up by solid phase extraction(SPE)with a neutral aluminum oxide cartridge and a florisil cartridge.The residue was determined by GC with ECD-detector,using external standard method.The liner range was 0.002 5~0.250 0 μg·mL-1 for isoprothiolane.The correlation coefficients were 0.9996 for isoprothiolane.The regression equation was y= 57194.11x-71.82.The average recoveries of isoprothiolane in spiked samples ranged from 87.8%~106.7%,and the relative standard deviations were between 4.35%~9.91%.The limit of detection was 0.005 mg·kg-1 in method.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The gas chromatographic method was used to determine isoprothiolane residues in rice.The isoprothiolane residue in the test sample was extracted with acetonitrile.After the extracts was evaporated,the residues were cleaned up by solid phase extraction(SPE)with a neutral aluminum oxide cartridge and a florisil cartridge.The residue was determined by GC with ECD-detector,using external standard method.The liner range was 0.002 5~0.250 0 μg·mL-1 for isoprothiolane.The correlation coefficients were 0.9996 for isoprothiolane.The regression equation was y= 57194.11x-71.82.The average recoveries of isoprothiolane in spiked samples ranged from 87.8%~106.7%,and the relative standard deviations were between 4.35%~9.91%.The limit of detection was 0.005 mg·kg-1 in method.

Key concepts: Cartridge, Chromatography, Residue (chemistry), Detection limit, Chemistry, Relative standard deviation, Solid phase extraction, Extraction (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Isoprothiolane Residues in Aquatic Products by Gas Chromatography — Research Paper | ScholarLens