Simultaneous determination of ten nucleoside and nucleobase components in Hulisan tablets by HPLC
Mao Kun-ju
Abstract
Mao Kun-ju
Abstract
Objective: To establish an HPLC method for simultaneous determination of ten nucleoside and nucleobase components in Hulisan tablets. Methods: The assay was performed on a Waters XselectTMHss C18column( 4. 6 mm ×250 mm,5 μm); the mobile phase consisted of methanol( phase A)- 0. 1% orthophosphoric acid water( phase B) with gradient elution at a flow rate of 0. 6 m L·min- 1; the column temperature was 30 ℃,and the detection wavelength was260 nm. Results: The investigated compounds including adenin,cytidine,hypoxanthine,xanthine,uridine,adenosine,2- deoxyuridine,guanosin,2- deoxidation inosine and thymidine showed good linearity( r≥0. 9994) in the ranges of9. 07- 181. 44,5. 03- 100. 50,2. 03- 40. 60,1. 54- 30. 87,3. 57- 71. 47,1. 25- 25. 08,3. 01- 60. 24,2. 02- 40. 48,0. 52- 10. 40 and 1. 05- 21. 00 μg·m L- 1,respectively. The average recoveries( n =6) ranged 96. 2%-103. 5% with RSD≤2. 6%. Conclusion: The HPLC method developed for simultaneous determination of nucleoside components was simple and valid. It could be used for quality evaluation and quality control of the Hulisan tablets.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: To establish an HPLC method for simultaneous determination of ten nucleoside and nucleobase components in Hulisan tablets. Methods: The assay was performed on a Waters XselectTMHss C18column( 4. 6 mm ×250 mm,5 μm); the mobile phase consisted of methanol( phase A)- 0. 1% orthophosphoric acid water( phase B) with gradient elution at a flow rate of 0. 6 m L·min- 1; the column temperature was 30 ℃,and the detection wavelength was260 nm. Results: The investigated compounds including adenin,cytidine,hypoxanthine,xanthine,uridine,adenosine,2- deoxyuridine,guanosin,2- deoxidation inosine and thymidine showed good linearity( r≥0. 9994) in the ranges of9. 07- 181. 44,5. 03- 100. 50,2. 03- 40. 60,1. 54- 30. 87,3. 57- 71. 47,1. 25- 25. 08,3. 01- 60. 24,2. 02- 40. 48,0. 52- 10. 40 and 1. 05- 21. 00 μg·m L- 1,respectively. The average recoveries( n =6) ranged 96. 2%-103. 5% with RSD≤2. 6%. Conclusion: The HPLC method developed for simultaneous determination of nucleoside components was simple and valid. It could be used for quality evaluation and quality control of the Hulisan tablets.
Key concepts: Chemistry, Chromatography, Hypoxanthine, Nucleoside, Inosine, Cytidine, High-performance liquid chromatography, Nucleobase