2014Military Medical Journal of Southeast ChinaRequires access

Evaluation of the quality and performance of self-made C-reactive protein test kit

Shi Guo-mi

Open publisher page 0 citations

Abstract

Objective To evaluate the quality and performance of self-made C-reactive protein test kit(latex immunoturbidimetry).Methods The limitation of detection,precision,linearity,recovery,expiry term was measured.200 blood samples were used for the comparative study with imports.Results Limitation of detection:0.72 mg/L.Precision:the within-run relative standard deviations of two different concentration samples were 3.09% and 6.75%.The day to day relative standard deviations of two different concentration samples were 6.47% and 6.84%.Linearity:the linear range was from 1 mg/L to 215 mg/L.The correlation coefficient was0.99.Accuracy:the average recovery was 112.5%.The system error was less than 1/2TEa.Expiry term:18 months.Contrast experiment:the results between self-made C-reactive protein test kit and imports had no significant difference.Conclusion The test kit is a valueable diagnostic tool for C-reactive protein rapid and accurate detection.

About this research paper

What this paper is about

Objective To evaluate the quality and performance of self-made C-reactive protein test kit(latex immunoturbidimetry).Methods The limitation of detection,precision,linearity,recovery,expiry term was measured.200 blood samples were used for the comparative study with imports.Results Limitation of detection:0.72 mg/L.Precision:the within-run relative standard deviations of two different concentration samples were 3.09% and 6.75%.The day to day relative standard deviations of two different concentration samples were 6.47% and 6.84%.Linearity:the linear range was from 1 mg/L to 215 mg/L.The correlation coefficient was0.99.Accuracy:the average recovery was 112.5%.The system error was less than 1/2TEa.Expiry term:18 months.Contrast experiment:the results between self-made C-reactive protein test kit and imports had no significant difference.Conclusion The test kit is a valueable diagnostic tool for C-reactive protein rapid and accurate detection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To evaluate the quality and performance of self-made C-reactive protein test kit(latex immunoturbidimetry).Methods The limitation of detection,precision,linearity,recovery,expiry term was measured.200 blood samples were used for the comparative study with imports.Results Limitation of detection:0.72 mg/L.Precision:the within-run relative standard deviations of two different concentration samples were 3.09% and 6.75%.The day to day relative standard deviations of two different concentration samples were 6.47% and 6.84%.Linearity:the linear range was from 1 mg/L to 215 mg/L.The correlation coefficient was0.99.Accuracy:the average recovery was 112.5%.The system error was less than 1/2TEa.Expiry term:18 months.Contrast experiment:the results between self-made C-reactive protein test kit and imports had no significant difference.Conclusion The test kit is a valueable diagnostic tool for C-reactive protein rapid and accurate detection.

Key concepts: Medicine, Relative standard deviation, Linearity, Correlation coefficient, Coefficient of variation, Standard deviation, Chromatography, Statistics

Related papers

Back to paper searchBrowse research topicsOriginal source
Evaluation of the quality and performance of self-made C-reactive protein test kit — Research Paper | ScholarLens