Evaluation of the quality and performance of self-made C-reactive protein test kit
Shi Guo-mi
Abstract
Shi Guo-mi
Abstract
Objective To evaluate the quality and performance of self-made C-reactive protein test kit(latex immunoturbidimetry).Methods The limitation of detection,precision,linearity,recovery,expiry term was measured.200 blood samples were used for the comparative study with imports.Results Limitation of detection:0.72 mg/L.Precision:the within-run relative standard deviations of two different concentration samples were 3.09% and 6.75%.The day to day relative standard deviations of two different concentration samples were 6.47% and 6.84%.Linearity:the linear range was from 1 mg/L to 215 mg/L.The correlation coefficient was0.99.Accuracy:the average recovery was 112.5%.The system error was less than 1/2TEa.Expiry term:18 months.Contrast experiment:the results between self-made C-reactive protein test kit and imports had no significant difference.Conclusion The test kit is a valueable diagnostic tool for C-reactive protein rapid and accurate detection.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To evaluate the quality and performance of self-made C-reactive protein test kit(latex immunoturbidimetry).Methods The limitation of detection,precision,linearity,recovery,expiry term was measured.200 blood samples were used for the comparative study with imports.Results Limitation of detection:0.72 mg/L.Precision:the within-run relative standard deviations of two different concentration samples were 3.09% and 6.75%.The day to day relative standard deviations of two different concentration samples were 6.47% and 6.84%.Linearity:the linear range was from 1 mg/L to 215 mg/L.The correlation coefficient was0.99.Accuracy:the average recovery was 112.5%.The system error was less than 1/2TEa.Expiry term:18 months.Contrast experiment:the results between self-made C-reactive protein test kit and imports had no significant difference.Conclusion The test kit is a valueable diagnostic tool for C-reactive protein rapid and accurate detection.
Key concepts: Medicine, Relative standard deviation, Linearity, Correlation coefficient, Coefficient of variation, Standard deviation, Chromatography, Statistics