2011•Rock and Mineral AnalysisRequires access

Determination of Trace Rare Earth Elements in Soils and Sediments by Inductively Coupled Plasma-Mass Spectrometry with Microwave Digestion

Wei Xin-hong

Open publisher page 1 citations

Abstract

A method to determine concentrations of 15 rare earth elements in soil and sediments by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) with microwave digestion is reported in this paper.Experimental conditions such as sample dissolution reagents,microwave digestion procedure,standard solution preparation,mass spectrum interferences and internal standards were studied.The samples were dissolved completely by the addition of HF acid.The dissolving rate of rare earth elements(REEs) was improved by using mix HNO3-HF-H2O2 reagent.The interference effects among REEs can be minimized by using matched calibration solutions with a similar composition to soil and sediments.Polyatomic ions inferences were calibrated by equivalent concentrations,calculated by the measured ratios of MO+/M+ and MOH+/M+ of individual La,Ce,Pr,Nd and Ba solution.103Rh was selected as an internal standard to calibrate the analytical signal drift.The detection limits for the method were 1.2-7.1 ng/g,the relative standard deviation(RSD,n=6) was less than 5.3% and recoveries were 86.1%-110.1%.The accuracy and precision of the method were validated by reference materials and the results were consistent with the certified values.This method is simple,rapid,has good reproducibility and wide linearity,all of which meets the requirements for the analysis of large batches.

About this research paper

What this paper is about

A method to determine concentrations of 15 rare earth elements in soil and sediments by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) with microwave digestion is reported in this paper.Experimental conditions such as sample dissolution reagents,microwave digestion procedure,standard solution preparation,mass spectrum interferences and internal standards were studied.The samples were dissolved completely by the addition of HF acid.The dissolving rate of rare earth elements(REEs) was improved by using mix HNO3-HF-H2O2 reagent.The interference effects among REEs can be minimized by using matched calibration solutions with a similar composition to soil and sediments.Polyatomic ions inferences were calibrated by equivalent concentrations,calculated by the measured ratios of MO+/M+ and MOH+/M+ of individual La,Ce,Pr,Nd and Ba solution.103Rh was selected as an internal standard to calibrate the analytical signal drift.The detection limits for the method were 1.2-7.1 ng/g,the relative standard deviation(RSD,n=6) was less than 5.3% and recoveries were 86.1%-110.1%.The accuracy and precision of the method were validated by reference materials and the results were consistent with the certified values.This method is simple,rapid,has good reproducibility and wide linearity,all of which meets the requirements for the analysis of large batches.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method to determine concentrations of 15 rare earth elements in soil and sediments by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS) with microwave digestion is reported in this paper.Experimental conditions such as sample dissolution reagents,microwave digestion procedure,standard solution preparation,mass spectrum interferences and internal standards were studied.The samples were dissolved completely by the addition of HF acid.The dissolving rate of rare earth elements(REEs) was improved by using mix HNO3-HF-H2O2 reagent.The interference effects among REEs can be minimized by using matched calibration solutions with a similar composition to soil and sediments.Polyatomic ions inferences were calibrated by equivalent concentrations,calculated by the measured ratios of MO+/M+ and MOH+/M+ of individual La,Ce,Pr,Nd and Ba solution.103Rh was selected as an internal standard to calibrate the analytical signal drift.The detection limits for the method were 1.2-7.1 ng/g,the relative standard deviation(RSD,n=6) was less than 5.3% and recoveries were 86.1%-110.1%.The accuracy and precision of the method were validated by reference materials and the results were consistent with the certified values.This method is simple,rapid,has good reproducibility and wide linearity,all of which meets the requirements for the analysis of large batches.

Key concepts: Chemistry, Inductively coupled plasma mass spectrometry, Certified reference materials, Mass spectrometry, Analytical Chemistry (journal), Microwave digestion, Dissolution, Reagent

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Trace Rare Earth Elements in Soils and Sediments by Inductively Coupled Plasma-Mass Spectrometry with Microwave Digestion — Research Paper | ScholarLens