Abstract
Gao Jingjing
Abstract
Abstrat: Using a HF-HNO3 system with high-pressure closed digestion,a method to determine concentrations of fifteen rare earth elements(REEs) in marine sediments was studied by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS).Experimental conditions such as mass spectrum interferences,digestion methods and acid systems have been investigated.Compared to electric heating plate digestion and microwave digestion,highpressure closed digestion has the advantages of using less acid,achieving complete digestion and causing less damage to the digestion process.The correction equation effectively calibrated polyatomic ions interferences formed by Ba and light rare earth elements.The marine sediment samples were dissolved completely by HF-HNO3 system,and the relative error(RE) was less than 5%.The method detection limits were 3-15 ng/g.The proposed method was validated by the marine sediment reference materials GBW 07309,GBW 07311 and GBW 07313.The results were consistent with certified values,and the relative standard deviation(RSD) and relative error were both less than 5%.The determination precision(RSD,n=6) of the Yangtze River estuary sediment samples was less than 5%,and the recoveries were 95.8%-104%.This method has a low detection limit with high precision and accuracy,all of which meet the requirements to analyze a large number of marine sediment samples.
OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Abstrat: Using a HF-HNO3 system with high-pressure closed digestion,a method to determine concentrations of fifteen rare earth elements(REEs) in marine sediments was studied by Inductively Coupled Plasma-Mass Spectrometry(ICP-MS).Experimental conditions such as mass spectrum interferences,digestion methods and acid systems have been investigated.Compared to electric heating plate digestion and microwave digestion,highpressure closed digestion has the advantages of using less acid,achieving complete digestion and causing less damage to the digestion process.The correction equation effectively calibrated polyatomic ions interferences formed by Ba and light rare earth elements.The marine sediment samples were dissolved completely by HF-HNO3 system,and the relative error(RE) was less than 5%.The method detection limits were 3-15 ng/g.The proposed method was validated by the marine sediment reference materials GBW 07309,GBW 07311 and GBW 07313.The results were consistent with certified values,and the relative standard deviation(RSD) and relative error were both less than 5%.The determination precision(RSD,n=6) of the Yangtze River estuary sediment samples was less than 5%,and the recoveries were 95.8%-104%.This method has a low detection limit with high precision and accuracy,all of which meet the requirements to analyze a large number of marine sediment samples.
Key concepts: Inductively coupled plasma mass spectrometry, Sediment, Chemistry, Digestion (alchemy), Mass spectrometry, Detection limit, Certified reference materials, Inductively coupled plasma