Simultaneous Determination of Six Effective Components in Qingre Jiedu Capsules by HPLC
Lin Yuan-fen
Abstract
Lin Yuan-fen
Abstract
Objective: A HPLC method was established for the determination of chlorogenic acid,geniposide,luteolin,baicalin,phillyrin and wogonin in Qingrejiedu capsules. Method: Eclipse XDB column( 4. 6 mm × 150 mm,5 μm) was adopted and eluted in gradient with the mobile phase of acetonitrile-0. 4%phosphoric acid solution. The flow rate was 0. 80 m L ·min- 1. The detection wavelength was set at 275 nm.Chlorogenic acid, geniposide, luteolin, baicalin, phillyrin and wogonin could be completely separated from adjacent mass spectra peaks. Result: The HPLC method showed a good linear range of 7. 83-313 mg·L- 1( r =0. 999 9) for chlorogenic acid,4. 30-132 mg·L- 1( r = 0. 999 8) for geniposide,0. 836-33. 5 mg·L- 1( r =0. 999 7) for luteolin,4. 36-349 mg·L- 1( r = 1. 000 0) for baicalin,0. 731-58. 4 mg·L- 1( r = 0. 999 7) for phillyrin and 0. 314-12. 6 mg·L- 1( r = 0. 999 7) for wogonin,with the recoveries above 98%. Conclusion: The method is simple,accurate and highly reproducible and so can be used to remove interferences from other components and evaluate the quality control of the preparation.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective: A HPLC method was established for the determination of chlorogenic acid,geniposide,luteolin,baicalin,phillyrin and wogonin in Qingrejiedu capsules. Method: Eclipse XDB column( 4. 6 mm × 150 mm,5 μm) was adopted and eluted in gradient with the mobile phase of acetonitrile-0. 4%phosphoric acid solution. The flow rate was 0. 80 m L ·min- 1. The detection wavelength was set at 275 nm.Chlorogenic acid, geniposide, luteolin, baicalin, phillyrin and wogonin could be completely separated from adjacent mass spectra peaks. Result: The HPLC method showed a good linear range of 7. 83-313 mg·L- 1( r =0. 999 9) for chlorogenic acid,4. 30-132 mg·L- 1( r = 0. 999 8) for geniposide,0. 836-33. 5 mg·L- 1( r =0. 999 7) for luteolin,4. 36-349 mg·L- 1( r = 1. 000 0) for baicalin,0. 731-58. 4 mg·L- 1( r = 0. 999 7) for phillyrin and 0. 314-12. 6 mg·L- 1( r = 0. 999 7) for wogonin,with the recoveries above 98%. Conclusion: The method is simple,accurate and highly reproducible and so can be used to remove interferences from other components and evaluate the quality control of the preparation.
Key concepts: Baicalin, Wogonin, Chromatography, Chlorogenic acid, Chemistry, High-performance liquid chromatography, Phosphoric acid, Gradient elution