2006•Yaowu fenxi zazhiRequires access

Study on the quality control standard of Huxin capsules

Deng Shao-wei

Open publisher page 0 citations

Abstract

Objective:To establish the quality control standard of Huxin capsules.Method:Fructus Evodiae,Rhi- zoma Acori Tatarinowii,Borneolum Syntheticum,and Radix et Rhizoma Notoginseng were identified by TLC.The content of icariin in Huxin capsules was determined by HPLC.Alltima C_(18) column(250 mm×4.6 mm,5 μm) was used.The mobile phase was a mixture of acetonitrile-water-glacial acetic acid(27:73:0.5),column temperature at 30 ℃,the flow rate was 1 mL·min~(-1) and the detection wavelength was at 270 nm.Results:The calibration curve was linear in the range of 0.1-3.1 μg for icariin (r=0.9999,n=8).The mean recovery of icariin was 100.5%,RSD=1.2%.Conclusion:This method is simple,reliable,accurate,and used to control the quality of Huxin capsules.

About this research paper

What this paper is about

Objective:To establish the quality control standard of Huxin capsules.Method:Fructus Evodiae,Rhi- zoma Acori Tatarinowii,Borneolum Syntheticum,and Radix et Rhizoma Notoginseng were identified by TLC.The content of icariin in Huxin capsules was determined by HPLC.Alltima C_(18) column(250 mm×4.6 mm,5 μm) was used.The mobile phase was a mixture of acetonitrile-water-glacial acetic acid(27:73:0.5),column temperature at 30 ℃,the flow rate was 1 mL·min~(-1) and the detection wavelength was at 270 nm.Results:The calibration curve was linear in the range of 0.1-3.1 μg for icariin (r=0.9999,n=8).The mean recovery of icariin was 100.5%,RSD=1.2%.Conclusion:This method is simple,reliable,accurate,and used to control the quality of Huxin capsules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish the quality control standard of Huxin capsules.Method:Fructus Evodiae,Rhi- zoma Acori Tatarinowii,Borneolum Syntheticum,and Radix et Rhizoma Notoginseng were identified by TLC.The content of icariin in Huxin capsules was determined by HPLC.Alltima C_(18) column(250 mm×4.6 mm,5 μm) was used.The mobile phase was a mixture of acetonitrile-water-glacial acetic acid(27:73:0.5),column temperature at 30 ℃,the flow rate was 1 mL·min~(-1) and the detection wavelength was at 270 nm.Results:The calibration curve was linear in the range of 0.1-3.1 μg for icariin (r=0.9999,n=8).The mean recovery of icariin was 100.5%,RSD=1.2%.Conclusion:This method is simple,reliable,accurate,and used to control the quality of Huxin capsules.

Key concepts: Icariin, Chemistry, Chromatography, Calibration curve, High-performance liquid chromatography, Acetic acid, Panax notoginseng, Quality standard

Related papers

Back to paper searchBrowse research topicsOriginal source
Study on the quality control standard of Huxin capsules — Research Paper | ScholarLens