2015•China FeedRequires access

Determination of water soluble chloride in feed by ion chromatography

Zhang Zhenzhe

Open publisher page 0 citations

Abstract

This experiment established a method for the content determination of the water soluble chloride in feed by ion chromatography.The samples were extracted by water,then were carried out on a metrosep A supp 4-250/4.0 anion analysis column using 3.2 mmol/L Na2CO3 and 1.0 mmol/L Na HCO3 as eluent solution at a flow rate of 1.0 m L/min.The results showed that the correlation coefficient was above 0.999 in the range of 4 ~ 100 μg/m L,and the detection limit was0.04 μg/g.The recovery rate was in the range of 91.7% ~ 100.2% by adding different concentrations of standard substance.In conclusion,this method was operated easily,with very high sensitive and reliable characteristic,and it was skillful and efficient for determination of large batches of samples.

About this research paper

What this paper is about

This experiment established a method for the content determination of the water soluble chloride in feed by ion chromatography.The samples were extracted by water,then were carried out on a metrosep A supp 4-250/4.0 anion analysis column using 3.2 mmol/L Na2CO3 and 1.0 mmol/L Na HCO3 as eluent solution at a flow rate of 1.0 m L/min.The results showed that the correlation coefficient was above 0.999 in the range of 4 ~ 100 μg/m L,and the detection limit was0.04 μg/g.The recovery rate was in the range of 91.7% ~ 100.2% by adding different concentrations of standard substance.In conclusion,this method was operated easily,with very high sensitive and reliable characteristic,and it was skillful and efficient for determination of large batches of samples.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This experiment established a method for the content determination of the water soluble chloride in feed by ion chromatography.The samples were extracted by water,then were carried out on a metrosep A supp 4-250/4.0 anion analysis column using 3.2 mmol/L Na2CO3 and 1.0 mmol/L Na HCO3 as eluent solution at a flow rate of 1.0 m L/min.The results showed that the correlation coefficient was above 0.999 in the range of 4 ~ 100 μg/m L,and the detection limit was0.04 μg/g.The recovery rate was in the range of 91.7% ~ 100.2% by adding different concentrations of standard substance.In conclusion,this method was operated easily,with very high sensitive and reliable characteristic,and it was skillful and efficient for determination of large batches of samples.

Key concepts: Chemistry, Ion chromatography, Chromatography, Chloride, Detection limit, Column chromatography, Volumetric flow rate, Correlation coefficient

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of water soluble chloride in feed by ion chromatography — Research Paper | ScholarLens