2007•Chemical ReagentsRequires access

Determination of sulfur and phosphorus contents in scale from vacuum pan by ion-exchange chromatography

Siyuan Zhang

Open publisher page 0 citations

Abstract

An ion-exchange chromatographic method was established to measure major anions in scale deposited in vacuum pan.9 mmol/L of NaOH solution was selected as the eluent,and the contents of SO2-4 and PO34 could be determined exactly at a flow rate of 1.00 mL/min.It showed that this method had a good correlation(r≥0.999 7),the added standard recovery was 100.0%~102.2% and 100.6%~103.4%,respectively,and the detection limit was 0.030 μg/mL and 0.048 μg/mL,respectively.Compared with the results of national standard,the ion-exchange chromatography had better accuracy and reproducibility and it was easy to operate.

About this research paper

What this paper is about

An ion-exchange chromatographic method was established to measure major anions in scale deposited in vacuum pan.9 mmol/L of NaOH solution was selected as the eluent,and the contents of SO2-4 and PO34 could be determined exactly at a flow rate of 1.00 mL/min.It showed that this method had a good correlation(r≥0.999 7),the added standard recovery was 100.0%~102.2% and 100.6%~103.4%,respectively,and the detection limit was 0.030 μg/mL and 0.048 μg/mL,respectively.Compared with the results of national standard,the ion-exchange chromatography had better accuracy and reproducibility and it was easy to operate.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An ion-exchange chromatographic method was established to measure major anions in scale deposited in vacuum pan.9 mmol/L of NaOH solution was selected as the eluent,and the contents of SO2-4 and PO34 could be determined exactly at a flow rate of 1.00 mL/min.It showed that this method had a good correlation(r≥0.999 7),the added standard recovery was 100.0%~102.2% and 100.6%~103.4%,respectively,and the detection limit was 0.030 μg/mL and 0.048 μg/mL,respectively.Compared with the results of national standard,the ion-exchange chromatography had better accuracy and reproducibility and it was easy to operate.

Key concepts: Chemistry, Ion chromatography, Detection limit, Chromatography, Sulfur, Column chromatography, Ion exchange, Phosphorus

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of sulfur and phosphorus contents in scale from vacuum pan by ion-exchange chromatography — Research Paper | ScholarLens