2011•Rock and Mineral AnalysisRequires access

Determination of Glyphosate in Drinking Water by Ion Chromatography

Weirong Wang

Open publisher page 1 citations

Abstract

A method for determination of glyphosate in water by ion chromatography was established in this paper.After removed residual chlorine by adding ascorbic acid and filtrated by micropore filtrer membrance,the water samples were directly injected into IC.The separation was carried out on IonPac AS11-HC anion-exchange column and the eluent was 20 mmol/L KOH at flow rate of 1.00 mL/min.The injection volume was 100 μL.The linearity of the method is from 0 to 1.5 mg/L.The detection limit was 0.1 mg/L.The recoveries were from 95% to 106%,and RSD was from 5.08% to 7.09%.The experiments verified that the method was simple,sensitive,and accurate.

About this research paper

What this paper is about

A method for determination of glyphosate in water by ion chromatography was established in this paper.After removed residual chlorine by adding ascorbic acid and filtrated by micropore filtrer membrance,the water samples were directly injected into IC.The separation was carried out on IonPac AS11-HC anion-exchange column and the eluent was 20 mmol/L KOH at flow rate of 1.00 mL/min.The injection volume was 100 μL.The linearity of the method is from 0 to 1.5 mg/L.The detection limit was 0.1 mg/L.The recoveries were from 95% to 106%,and RSD was from 5.08% to 7.09%.The experiments verified that the method was simple,sensitive,and accurate.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method for determination of glyphosate in water by ion chromatography was established in this paper.After removed residual chlorine by adding ascorbic acid and filtrated by micropore filtrer membrance,the water samples were directly injected into IC.The separation was carried out on IonPac AS11-HC anion-exchange column and the eluent was 20 mmol/L KOH at flow rate of 1.00 mL/min.The injection volume was 100 μL.The linearity of the method is from 0 to 1.5 mg/L.The detection limit was 0.1 mg/L.The recoveries were from 95% to 106%,and RSD was from 5.08% to 7.09%.The experiments verified that the method was simple,sensitive,and accurate.

Key concepts: Chemistry, Ion chromatography, Chromatography, Detection limit, Column chromatography, Ascorbic acid, Chlorine, Glyphosate

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Glyphosate in Drinking Water by Ion Chromatography — Research Paper | ScholarLens