2010Gao dianya jishuRequires access

Electromagnetic Environment and Corona Control Measures of UHV Substation

Xingfa Liu

Open publisher page 3 citations

Abstract

The 1000 kV Jindongnan-Nanyang-Jingmen UHV AC demonstration project have been on commercial run.UHV substation integrates a series of high-voltage and secondary electrical equipments which bring out electromagnetic environment deserving more attention.If the electromagnetic environment of substation is severe,it will affect the neighboring radio stations' normal work and also the residents around and workers at the UHV substation.So we test the electromagnetic environment parameters of Chinese UHV AC substation,and test results indicate that the radio interference data 20 m away from UHV substations satisfies requests of environment protection,audible noise data is equivalent to 500 kV substations.Electromagnetic field is a bit larger than that of 500 kV substations.Paper puts forward some measurements,for instance,suitable pipe bus dimension and fittings model,to achieve electromagnetic environmental amendatory.

About this research paper

What this paper is about

The 1000 kV Jindongnan-Nanyang-Jingmen UHV AC demonstration project have been on commercial run.UHV substation integrates a series of high-voltage and secondary electrical equipments which bring out electromagnetic environment deserving more attention.If the electromagnetic environment of substation is severe,it will affect the neighboring radio stations' normal work and also the residents around and workers at the UHV substation.So we test the electromagnetic environment parameters of Chinese UHV AC substation,and test results indicate that the radio interference data 20 m away from UHV substations satisfies requests of environment protection,audible noise data is equivalent to 500 kV substations.Electromagnetic field is a bit larger than that of 500 kV substations.Paper puts forward some measurements,for instance,suitable pipe bus dimension and fittings model,to achieve electromagnetic environmental amendatory.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The 1000 kV Jindongnan-Nanyang-Jingmen UHV AC demonstration project have been on commercial run.UHV substation integrates a series of high-voltage and secondary electrical equipments which bring out electromagnetic environment deserving more attention.If the electromagnetic environment of substation is severe,it will affect the neighboring radio stations' normal work and also the residents around and workers at the UHV substation.So we test the electromagnetic environment parameters of Chinese UHV AC substation,and test results indicate that the radio interference data 20 m away from UHV substations satisfies requests of environment protection,audible noise data is equivalent to 500 kV substations.Electromagnetic field is a bit larger than that of 500 kV substations.Paper puts forward some measurements,for instance,suitable pipe bus dimension and fittings model,to achieve electromagnetic environmental amendatory.

Key concepts: Electromagnetic environment, Electromagnetic interference, Engineering, Electrical engineering, Electromagnetic field, Electromagnetic compatibility, Noise (video), Interference (communication)

Related papers

Back to paper searchBrowse research topicsOriginal source
Electromagnetic Environment and Corona Control Measures of UHV Substation — Research Paper | ScholarLens