2013IEEE Transactions on Power DeliveryRequires access

Measurement of Electric Fields Around a 1000-kV UHV Substation

Naiyi Li, Xi Yang, Zongren Peng

Open publisher page 29 citations

Abstract

This paper investigates the power frequency electric fields around a 1000-kV ultra-high voltage (UHV) substation which is located in Jingmen, China. Detailed field measurements around this substation as well as numerical results in a 1000-kV area are provided. Most values observed are below the reference level indicated in the relevant national design guideline. Therefore, we can conclude that the power frequency electric fields around this UHV substation are safer for working personnel.

About this research paper

What this paper is about

This paper investigates the power frequency electric fields around a 1000-kV ultra-high voltage (UHV) substation which is located in Jingmen, China. Detailed field measurements around this substation as well as numerical results in a 1000-kV area are provided. Most values observed are below the reference level indicated in the relevant national design guideline. Therefore, we can conclude that the power frequency electric fields around this UHV substation are safer for working personnel.

Why it matters

OpenAlex reports 29 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This paper investigates the power frequency electric fields around a 1000-kV ultra-high voltage (UHV) substation which is located in Jingmen, China. Detailed field measurements around this substation as well as numerical results in a 1000-kV area are provided. Most values observed are below the reference level indicated in the relevant national design guideline. Therefore, we can conclude that the power frequency electric fields around this UHV substation are safer for working personnel.

Key concepts: Electrical engineering, Electric field, Voltage, Engineering, Electric power, High voltage, Power (physics), Physics