2006Journal of Practical Medical TechniquesRequires access

The Cerebral Hemodynamics Study by Using Multislice CT Perfusion Imaging in Normal Adult

Zhenwei Yao

Open publisher page 0 citations

Abstract

Objective To explore the application of multislice CT perfusion imaging in normal adult cerebral hemodynamics.Methods Routine CT was performed in 13 normal adults,then multislice CT perfusion imaging study was made by selecting the basal ganglia slice and its adjacent slice.The contrast material was bolus injected through antecubital vein ,while four layers of dynamic scans were performed for 50 seconds.These slice dynamic images were processed with the CT perfusion software package.Cerebral blood flow (CBF),cerebral blood volume (CBV),and mean transit time (MTT) were measured within the specific regions of interest (ROI) of the brain,and quantitative analysis was performed.Results A gradient of perfusion between gray matter and white matter was showed on multislice CT perfusion imaging in normal adults.CBF,CBV,and MTT were (54.7±11.3)ml/(min·100 g)、(2.9±0.5)ml/100 g、(3.4±0.6)s,respectively in the gray matter and (27.9±6.9)ml/(min·100 g)、(2.4±0.4)ml/100 g、(3.9±0.5)s respectively in the white matter.Conclusion Multislice CT perfusion scanning with deconvolution analysis is a method that has important practical advantages over previously available methods and provided a new imaging method for measuring the cerebral hemodynamics.

About this research paper

What this paper is about

Objective To explore the application of multislice CT perfusion imaging in normal adult cerebral hemodynamics.Methods Routine CT was performed in 13 normal adults,then multislice CT perfusion imaging study was made by selecting the basal ganglia slice and its adjacent slice.The contrast material was bolus injected through antecubital vein ,while four layers of dynamic scans were performed for 50 seconds.These slice dynamic images were processed with the CT perfusion software package.Cerebral blood flow (CBF),cerebral blood volume (CBV),and mean transit time (MTT) were measured within the specific regions of interest (ROI) of the brain,and quantitative analysis was performed.Results A gradient of perfusion between gray matter and white matter was showed on multislice CT perfusion imaging in normal adults.CBF,CBV,and MTT were (54.7±11.3)ml/(min·100 g)、(2.9±0.5)ml/100 g、(3.4±0.6)s,respectively in the gray matter and (27.9±6.9)ml/(min·100 g)、(2.4±0.4)ml/100 g、(3.9±0.5)s respectively in the white matter.Conclusion Multislice CT perfusion scanning with deconvolution analysis is a method that has important practical advantages over previously available methods and provided a new imaging method for measuring the cerebral hemodynamics.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To explore the application of multislice CT perfusion imaging in normal adult cerebral hemodynamics.Methods Routine CT was performed in 13 normal adults,then multislice CT perfusion imaging study was made by selecting the basal ganglia slice and its adjacent slice.The contrast material was bolus injected through antecubital vein ,while four layers of dynamic scans were performed for 50 seconds.These slice dynamic images were processed with the CT perfusion software package.Cerebral blood flow (CBF),cerebral blood volume (CBV),and mean transit time (MTT) were measured within the specific regions of interest (ROI) of the brain,and quantitative analysis was performed.Results A gradient of perfusion between gray matter and white matter was showed on multislice CT perfusion imaging in normal adults.CBF,CBV,and MTT were (54.7±11.3)ml/(min·100 g)、(2.9±0.5)ml/100 g、(3.4±0.6)s,respectively in the gray matter and (27.9±6.9)ml/(min·100 g)、(2.4±0.4)ml/100 g、(3.9±0.5)s respectively in the white matter.Conclusion Multislice CT perfusion scanning with deconvolution analysis is a method that has important practical advantages over previously available methods and provided a new imaging method for measuring the cerebral hemodynamics.

Key concepts: Medicine, Multislice, Cerebral blood flow, Perfusion scanning, Perfusion, Nuclear medicine, White matter, Blood volume

Related papers

Back to paper searchBrowse research topicsOriginal source
The Cerebral Hemodynamics Study by Using Multislice CT Perfusion Imaging in Normal Adult — Research Paper | ScholarLens