2002Chinese Journal of Hospital PharmacyRequires access

HPLC determination of tinidazole contents in tinidazole gel

Wang Yan

Open publisher page 0 citations

Abstract

OBJECTIVE To prepare a tinidazole gel and establish an HPLC method with metronidazole as internal standard to determine the content. METHODS The chromatographic column; Hypersil-C18 column. Mobile phase:methanol-water-36%acetic acid (30:70:0.5). Flow rate: 1.0 mL·min-1. Detection wavelength: 318 nm. Sensitivity: 0.08 AUFS. RESULTS The calibration curve was linear in the range of 41.84-125.52 mg·L-1 ( r = 0. 9997). Average recovery was 97. 92 % with RSD 1.02%.CONCLUSIONS The method is accurate, rapid, and suitable for the quality-control of the gel.

About this research paper

What this paper is about

OBJECTIVE To prepare a tinidazole gel and establish an HPLC method with metronidazole as internal standard to determine the content. METHODS The chromatographic column; Hypersil-C18 column. Mobile phase:methanol-water-36%acetic acid (30:70:0.5). Flow rate: 1.0 mL·min-1. Detection wavelength: 318 nm. Sensitivity: 0.08 AUFS. RESULTS The calibration curve was linear in the range of 41.84-125.52 mg·L-1 ( r = 0. 9997). Average recovery was 97. 92 % with RSD 1.02%.CONCLUSIONS The method is accurate, rapid, and suitable for the quality-control of the gel.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To prepare a tinidazole gel and establish an HPLC method with metronidazole as internal standard to determine the content. METHODS The chromatographic column; Hypersil-C18 column. Mobile phase:methanol-water-36%acetic acid (30:70:0.5). Flow rate: 1.0 mL·min-1. Detection wavelength: 318 nm. Sensitivity: 0.08 AUFS. RESULTS The calibration curve was linear in the range of 41.84-125.52 mg·L-1 ( r = 0. 9997). Average recovery was 97. 92 % with RSD 1.02%.CONCLUSIONS The method is accurate, rapid, and suitable for the quality-control of the gel.

Key concepts: Tinidazole, Chromatography, Calibration curve, High-performance liquid chromatography, Chemistry, Content determination, Acetic acid, Methanol

Related papers

Back to paper searchBrowse research topicsOriginal source
HPLC determination of tinidazole contents in tinidazole gel — Research Paper | ScholarLens