Clinical value of PET-CT 3D mode brain image in the localizition of epileptic foci
Yinghua Li
Abstract
Yinghua Li
Abstract
Objective To assess the value of 18F-FDG PET cerebral 3D mode in the localization of epileptic foci.Method 13 cases with epilepsy included 9 cases of primary epilepsy and 4 cases of secondary epilepsy.The brain scan with 3D mode was performed on all the patients and the images were analyzed by eyes and semi-quantitative method by two experienced nuclear medicine physicians.The scalp electroencephalogram(EEG)was performed on all the patients,and electrocorticogram(EcoG) or depth electroencephalogram(DEEG) were performed on 2 cases to verify the PET results,MRI and/or CT examination were obtained in 12 cases.Results 92.3% was abnormal displaying hypometabolic foci on PET imaging(12/13).PET was more sensitive than EEG and MRI/CT detecting the lesions(92.3℅,69.2℅ and 33.3℅,respectively,χ2=14.3 and 35.0,P0.01).Solitary lesion detection rate of PET was 61.5%,which was higher than EEG(61.5% vs.38.4℅,χ2 =23.1,P0.01).Compared with golden standard of EcoG or DEEG,the sensitivity and specificity of PET localizing the epileptic foci were 95℅ and 89℅.Conclusion 18 F-FDG PET is a sensitive and accurate image modality in the localization of epileptic foci and is useful to direct surgical treatment and orientate radiation therapy.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To assess the value of 18F-FDG PET cerebral 3D mode in the localization of epileptic foci.Method 13 cases with epilepsy included 9 cases of primary epilepsy and 4 cases of secondary epilepsy.The brain scan with 3D mode was performed on all the patients and the images were analyzed by eyes and semi-quantitative method by two experienced nuclear medicine physicians.The scalp electroencephalogram(EEG)was performed on all the patients,and electrocorticogram(EcoG) or depth electroencephalogram(DEEG) were performed on 2 cases to verify the PET results,MRI and/or CT examination were obtained in 12 cases.Results 92.3% was abnormal displaying hypometabolic foci on PET imaging(12/13).PET was more sensitive than EEG and MRI/CT detecting the lesions(92.3℅,69.2℅ and 33.3℅,respectively,χ2=14.3 and 35.0,P0.01).Solitary lesion detection rate of PET was 61.5%,which was higher than EEG(61.5% vs.38.4℅,χ2 =23.1,P0.01).Compared with golden standard of EcoG or DEEG,the sensitivity and specificity of PET localizing the epileptic foci were 95℅ and 89℅.Conclusion 18 F-FDG PET is a sensitive and accurate image modality in the localization of epileptic foci and is useful to direct surgical treatment and orientate radiation therapy.
Key concepts: Medicine, Epilepsy, Nuclear medicine, Electroencephalography, Scalp, Radiology, Lesion, Pathology