Comparative study and bias estimation on the results of serum bilirubin with different biochemical testing system among different hospitals

He Yi

Open publisher page 0 citations

Abstract

Objective To study the result comparability of serum total bilirubin(Tbil) and direct bilirubin(Dbil) on different biochemical detecting systems,so as to provide basis for mutual identification of test results among different hospitals.Methods According to CLSI EP9-A2 file,we analyzed the comparability of six self-built biochemical testing systems and aimed testing system by testing the fresh serum samples and calculating relative deviation.As a result,the correlation coefficient and the linear equation were obtained.The comparability of different investigating systems and clinical acceptability were judged according to CLIA'88 standard(half of total error).Results 1) There was no comparability of Dbil level between self-built testing system 2 and aimed testing system(r0.975). 2) The bias rates of self-built testing systems in different medical decision levels(system 1 at Tbil level 24.1μmol/L and 42.8μmol/L,Dbil level 6.8μmol/L and 29.8μmol/L;system 3 at Dbil level 6. 8μmol/L and 29.8μmol/L;system 4 and 6 at Tbil level 342μmol/L,Dbil level 29.8μmol/L) were all higher than the half of CLIA'88 standard,and no comparability was found between self-built testing systems and aimed testing system.Conclusion There are no comparability of bilirubin level between partial self-built testing systems and aimed testing system.It is important for performing comparative test about non-quality assessment items to insure the comparability of test results among different hospitals.

About this research paper

What this paper is about

Objective To study the result comparability of serum total bilirubin(Tbil) and direct bilirubin(Dbil) on different biochemical detecting systems,so as to provide basis for mutual identification of test results among different hospitals.Methods According to CLSI EP9-A2 file,we analyzed the comparability of six self-built biochemical testing systems and aimed testing system by testing the fresh serum samples and calculating relative deviation.As a result,the correlation coefficient and the linear equation were obtained.The comparability of different investigating systems and clinical acceptability were judged according to CLIA'88 standard(half of total error).Results 1) There was no comparability of Dbil level between self-built testing system 2 and aimed testing system(r0.975). 2) The bias rates of self-built testing systems in different medical decision levels(system 1 at Tbil level 24.1μmol/L and 42.8μmol/L,Dbil level 6.8μmol/L and 29.8μmol/L;system 3 at Dbil level 6. 8μmol/L and 29.8μmol/L;system 4 and 6 at Tbil level 342μmol/L,Dbil level 29.8μmol/L) were all higher than the half of CLIA'88 standard,and no comparability was found between self-built testing systems and aimed testing system.Conclusion There are no comparability of bilirubin level between partial self-built testing systems and aimed testing system.It is important for performing comparative test about non-quality assessment items to insure the comparability of test results among different hospitals.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To study the result comparability of serum total bilirubin(Tbil) and direct bilirubin(Dbil) on different biochemical detecting systems,so as to provide basis for mutual identification of test results among different hospitals.Methods According to CLSI EP9-A2 file,we analyzed the comparability of six self-built biochemical testing systems and aimed testing system by testing the fresh serum samples and calculating relative deviation.As a result,the correlation coefficient and the linear equation were obtained.The comparability of different investigating systems and clinical acceptability were judged according to CLIA'88 standard(half of total error).Results 1) There was no comparability of Dbil level between self-built testing system 2 and aimed testing system(r0.975). 2) The bias rates of self-built testing systems in different medical decision levels(system 1 at Tbil level 24.1μmol/L and 42.8μmol/L,Dbil level 6.8μmol/L and 29.8μmol/L;system 3 at Dbil level 6. 8μmol/L and 29.8μmol/L;system 4 and 6 at Tbil level 342μmol/L,Dbil level 29.8μmol/L) were all higher than the half of CLIA'88 standard,and no comparability was found between self-built testing systems and aimed testing system.Conclusion There are no comparability of bilirubin level between partial self-built testing systems and aimed testing system.It is important for performing comparative test about non-quality assessment items to insure the comparability of test results among different hospitals.

Key concepts: Comparability, Bilirubin, Statistics, Medicine, Mathematics, Internal medicine, Combinatorics

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparative study and bias estimation on the results of serum bilirubin with different biochemical testing system among different hospitals — Research Paper | ScholarLens