FAAS Determination of Palladium with FI-On-line Pre-enrichment

Zhou Fang-qin

Open publisher page 0 citations

Abstract

Preparation of a micro-column filled with model 717 ion-exchange resin,which was covered with a thin membrane of dimethylglyoxime dispersed in PVC,was described and used for the separation and pre-enrichment of Pd(Ⅱ).Based on a LZ-2000 FI-analyzer,manifold for enrichment of Pd(Ⅱ) on the microcolumn,elution of Pd(Ⅱ) from the column with a mixture of ethylenediamine and 20 g·L-1 NaOH solution(mixed in the ratio of 1+9 by volume),and introduction of the eluate into the atomizer of AAS instrument was designed,fabricated and its operation given in detail.Waste catalyst sample was treated with HCl(5+95) solution,and the insoluble residue was collected by filtration and dissolved in aqua regia.The solution,after adjusting its acidity to pH 2,was introduced into the FI-manifold for analysis.Rate and time of sample solution introduction were 7.5 mL·min-1 and 90 s.Linear relationship between values of absorbance and concentration of Pd(Ⅱ) was kept in the range within 1.25 mg·L-1.Detection limit(3S/N) of the method was found to be 15 μg·L-1.Precision and accuracy of the method were checked by analysis of 3 samples of geological standards and platinum ores,the results obtained were in consistency with the standard or known values,with values of RSD′s(n=7) less than 2.5%.

About this research paper

What this paper is about

Preparation of a micro-column filled with model 717 ion-exchange resin,which was covered with a thin membrane of dimethylglyoxime dispersed in PVC,was described and used for the separation and pre-enrichment of Pd(Ⅱ).Based on a LZ-2000 FI-analyzer,manifold for enrichment of Pd(Ⅱ) on the microcolumn,elution of Pd(Ⅱ) from the column with a mixture of ethylenediamine and 20 g·L-1 NaOH solution(mixed in the ratio of 1+9 by volume),and introduction of the eluate into the atomizer of AAS instrument was designed,fabricated and its operation given in detail.Waste catalyst sample was treated with HCl(5+95) solution,and the insoluble residue was collected by filtration and dissolved in aqua regia.The solution,after adjusting its acidity to pH 2,was introduced into the FI-manifold for analysis.Rate and time of sample solution introduction were 7.5 mL·min-1 and 90 s.Linear relationship between values of absorbance and concentration of Pd(Ⅱ) was kept in the range within 1.25 mg·L-1.Detection limit(3S/N) of the method was found to be 15 μg·L-1.Precision and accuracy of the method were checked by analysis of 3 samples of geological standards and platinum ores,the results obtained were in consistency with the standard or known values,with values of RSD′s(n=7) less than 2.5%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Preparation of a micro-column filled with model 717 ion-exchange resin,which was covered with a thin membrane of dimethylglyoxime dispersed in PVC,was described and used for the separation and pre-enrichment of Pd(Ⅱ).Based on a LZ-2000 FI-analyzer,manifold for enrichment of Pd(Ⅱ) on the microcolumn,elution of Pd(Ⅱ) from the column with a mixture of ethylenediamine and 20 g·L-1 NaOH solution(mixed in the ratio of 1+9 by volume),and introduction of the eluate into the atomizer of AAS instrument was designed,fabricated and its operation given in detail.Waste catalyst sample was treated with HCl(5+95) solution,and the insoluble residue was collected by filtration and dissolved in aqua regia.The solution,after adjusting its acidity to pH 2,was introduced into the FI-manifold for analysis.Rate and time of sample solution introduction were 7.5 mL·min-1 and 90 s.Linear relationship between values of absorbance and concentration of Pd(Ⅱ) was kept in the range within 1.25 mg·L-1.Detection limit(3S/N) of the method was found to be 15 μg·L-1.Precision and accuracy of the method were checked by analysis of 3 samples of geological standards and platinum ores,the results obtained were in consistency with the standard or known values,with values of RSD′s(n=7) less than 2.5%.

Key concepts: Aqua regia, Elution, Chemistry, Detection limit, Palladium, Absorbance, Chromatography, Analytical Chemistry (journal)