2003•Physical Testing and Chemical AnalysisRequires access

FIA-FAAS DETERMINATION OF TRACE AMOUNTS OF PLATINUM——ON LINE PRECONCENTRATION ON MICRO-COLUMN

Jing Xu, Ping Lu

Open publisher page 0 citations

Abstract

The PTFE microcolumn was packed with α-aminopyridine resin (size 0.12~0.15mm) to preconcentrate trace amounts of Pt(Ⅳ) from an acetate buffer solution of pH 3~4. A mixed solution of 2mol·L -1 HCl+0 3mol·L -1 NaClO_4 was used as eluent. The concentration factor was found to be 30 when the sampling volume was 15.2ml and the eluent volume was 0.27ml. The flow-rate of the sample solution was set at 7.6ml·min -1. The sampling frequency was 28 times per hour. Pt(Ⅳ) in the eluent was finally determined by FAAS. Detection limit (3σ) of this method was found to be 5.2μg·L -1. Average RSD % obtained by testing at concentration level of 1μg·ml -1 for 11 times, was 1.4%.

About this research paper

What this paper is about

The PTFE microcolumn was packed with α-aminopyridine resin (size 0.12~0.15mm) to preconcentrate trace amounts of Pt(Ⅳ) from an acetate buffer solution of pH 3~4. A mixed solution of 2mol·L -1 HCl+0 3mol·L -1 NaClO_4 was used as eluent. The concentration factor was found to be 30 when the sampling volume was 15.2ml and the eluent volume was 0.27ml. The flow-rate of the sample solution was set at 7.6ml·min -1. The sampling frequency was 28 times per hour. Pt(Ⅳ) in the eluent was finally determined by FAAS. Detection limit (3σ) of this method was found to be 5.2μg·L -1. Average RSD % obtained by testing at concentration level of 1μg·ml -1 for 11 times, was 1.4%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The PTFE microcolumn was packed with α-aminopyridine resin (size 0.12~0.15mm) to preconcentrate trace amounts of Pt(Ⅳ) from an acetate buffer solution of pH 3~4. A mixed solution of 2mol·L -1 HCl+0 3mol·L -1 NaClO_4 was used as eluent. The concentration factor was found to be 30 when the sampling volume was 15.2ml and the eluent volume was 0.27ml. The flow-rate of the sample solution was set at 7.6ml·min -1. The sampling frequency was 28 times per hour. Pt(Ⅳ) in the eluent was finally determined by FAAS. Detection limit (3σ) of this method was found to be 5.2μg·L -1. Average RSD % obtained by testing at concentration level of 1μg·ml -1 for 11 times, was 1.4%.

Key concepts: Column chromatography, Detection limit, Chromatography, Chemistry, Trace Amounts, Volume (thermodynamics), Analytical Chemistry (journal), Volumetric flow rate

Related papers

Back to paper searchBrowse research topicsOriginal source
FIA-FAAS DETERMINATION OF TRACE AMOUNTS OF PLATINUM——ON LINE PRECONCENTRATION ON MICRO-COLUMN — Research Paper | ScholarLens