2012•Physical Testing and Chemical AnalysisRequires access

FAAS Determination of Lead(II) in Sea Water with FI-Pre-enrichment on Micro-column

Yang Hong

Open publisher page 0 citations

Abstract

Trace amount of lead(Ⅱ) in sea water was pre-enriched on a micro-column packed with D412 chelate resin in a FI-system.Twenty mL of sea water sample was injected into the micro-column by wriggling pump at a rate of 3 mL·min-1,and Pb(Ⅱ) in the sample solution was adsorbed on the chelate resin.The micro-column was washed with 5 mL of 0.2 mol·L-1 NH4OAc solution to remove residual seawater.Pb(Ⅱ) was stripped from the micro-column with 4 mL of 4 mol·L-1 HNO3 solution at the rate of 7 mL·min-1.The eluate was transferred directly to the atomizer of the instrument.Peak-shaped absorption signal was recorded and the value of peak height was taken as parameter for quantification.By the enrichment procedure mentioned above,sensitivity for determination of the Pb(Ⅱ) was raised 35 times as compared with the procedure without pre-enrichment.Detection limit(3s) of the method was 1.3 μg·L-1.Test for recovery was made by standard addition method,giving value of recovery of 94.5% with RSD(n=6) of 2.2%.

About this research paper

What this paper is about

Trace amount of lead(Ⅱ) in sea water was pre-enriched on a micro-column packed with D412 chelate resin in a FI-system.Twenty mL of sea water sample was injected into the micro-column by wriggling pump at a rate of 3 mL·min-1,and Pb(Ⅱ) in the sample solution was adsorbed on the chelate resin.The micro-column was washed with 5 mL of 0.2 mol·L-1 NH4OAc solution to remove residual seawater.Pb(Ⅱ) was stripped from the micro-column with 4 mL of 4 mol·L-1 HNO3 solution at the rate of 7 mL·min-1.The eluate was transferred directly to the atomizer of the instrument.Peak-shaped absorption signal was recorded and the value of peak height was taken as parameter for quantification.By the enrichment procedure mentioned above,sensitivity for determination of the Pb(Ⅱ) was raised 35 times as compared with the procedure without pre-enrichment.Detection limit(3s) of the method was 1.3 μg·L-1.Test for recovery was made by standard addition method,giving value of recovery of 94.5% with RSD(n=6) of 2.2%.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Trace amount of lead(Ⅱ) in sea water was pre-enriched on a micro-column packed with D412 chelate resin in a FI-system.Twenty mL of sea water sample was injected into the micro-column by wriggling pump at a rate of 3 mL·min-1,and Pb(Ⅱ) in the sample solution was adsorbed on the chelate resin.The micro-column was washed with 5 mL of 0.2 mol·L-1 NH4OAc solution to remove residual seawater.Pb(Ⅱ) was stripped from the micro-column with 4 mL of 4 mol·L-1 HNO3 solution at the rate of 7 mL·min-1.The eluate was transferred directly to the atomizer of the instrument.Peak-shaped absorption signal was recorded and the value of peak height was taken as parameter for quantification.By the enrichment procedure mentioned above,sensitivity for determination of the Pb(Ⅱ) was raised 35 times as compared with the procedure without pre-enrichment.Detection limit(3s) of the method was 1.3 μg·L-1.Test for recovery was made by standard addition method,giving value of recovery of 94.5% with RSD(n=6) of 2.2%.

Key concepts: Seawater, Chelating resin, Elution, Detection limit, Chemistry, Analytical Chemistry (journal), Chromatography, Adsorption

Related papers

Back to paper searchBrowse research topicsOriginal source
FAAS Determination of Lead(II) in Sea Water with FI-Pre-enrichment on Micro-column — Research Paper | ScholarLens