Abstract

Objective: To establish a method to examine carbaryl and atrazine in drinking water by HPLC at same time.Methods:The examined sample was chosen by dichloromethane and rotary vapoured to almost dry,use methylalcohol solute it,use to set dosage,use methylalochol and water as fluent,detected by photodiode array detector,the speed of fluent was 1.0 m per minute.Results:The least limit of detection was 0.05 mg per litre and 0.15 mg per litre each one.In the scope of add standard solution from 10 mg to 30 mg,the rate of recovery was from 90.8% to 99.7%,the RSD from 0.72% to 1.20%.Conclusion:The method of examining carbaryl and atrazine in drinking water by HPLC has the accuracy in determining its speciality.The operation is fast.Its result is precise and believable.

About this research paper

What this paper is about

Objective: To establish a method to examine carbaryl and atrazine in drinking water by HPLC at same time.Methods:The examined sample was chosen by dichloromethane and rotary vapoured to almost dry,use methylalcohol solute it,use to set dosage,use methylalochol and water as fluent,detected by photodiode array detector,the speed of fluent was 1.0 m per minute.Results:The least limit of detection was 0.05 mg per litre and 0.15 mg per litre each one.In the scope of add standard solution from 10 mg to 30 mg,the rate of recovery was from 90.8% to 99.7%,the RSD from 0.72% to 1.20%.Conclusion:The method of examining carbaryl and atrazine in drinking water by HPLC has the accuracy in determining its speciality.The operation is fast.Its result is precise and believable.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To establish a method to examine carbaryl and atrazine in drinking water by HPLC at same time.Methods:The examined sample was chosen by dichloromethane and rotary vapoured to almost dry,use methylalcohol solute it,use to set dosage,use methylalochol and water as fluent,detected by photodiode array detector,the speed of fluent was 1.0 m per minute.Results:The least limit of detection was 0.05 mg per litre and 0.15 mg per litre each one.In the scope of add standard solution from 10 mg to 30 mg,the rate of recovery was from 90.8% to 99.7%,the RSD from 0.72% to 1.20%.Conclusion:The method of examining carbaryl and atrazine in drinking water by HPLC has the accuracy in determining its speciality.The operation is fast.Its result is precise and believable.

Key concepts: Carbaryl, Atrazine, High-performance liquid chromatography, Chromatography, Detection limit, Chemistry, Dichloromethane, Environmental chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous detection of carbaryl and atrazine in water by HPLC — Research Paper | ScholarLens