2011Huanjing jiance guanli yu jishuRequires access

Determination of Carbofuran,Carbaryl and Atrazine in Water by SPE-HPLC

Song Guo-qiang

Open publisher page 1 citations

Abstract

A method was established for determination of carbofuran,carbaryl and atrazine in water samples by solid phase extraction(SPE) and high performance liquid chromatograph(HPLC) using methanol-water as the mobile phase with gradient elution.The detection was made on a diode array detector at 220 nm.Dichloromethane was selected as eluting solvent.The results indicated that the good linear ranges were 0.200 mg/L~5.00 mg/L for carbofuran,and 0.020 mg/L~5.00 mg/L for carbaryl and atrazine.The detection limits of the method were 0.24 μg/L,0.019 μg/L and 0.035 μg/L for carbofuran,carbaryl and atrazine,respectively.The average recoveries of spiked standard materials at two quantity levels were from 84.0 % to 103%,and RSD was from 1.6% to 8.5%.

About this research paper

What this paper is about

A method was established for determination of carbofuran,carbaryl and atrazine in water samples by solid phase extraction(SPE) and high performance liquid chromatograph(HPLC) using methanol-water as the mobile phase with gradient elution.The detection was made on a diode array detector at 220 nm.Dichloromethane was selected as eluting solvent.The results indicated that the good linear ranges were 0.200 mg/L~5.00 mg/L for carbofuran,and 0.020 mg/L~5.00 mg/L for carbaryl and atrazine.The detection limits of the method were 0.24 μg/L,0.019 μg/L and 0.035 μg/L for carbofuran,carbaryl and atrazine,respectively.The average recoveries of spiked standard materials at two quantity levels were from 84.0 % to 103%,and RSD was from 1.6% to 8.5%.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A method was established for determination of carbofuran,carbaryl and atrazine in water samples by solid phase extraction(SPE) and high performance liquid chromatograph(HPLC) using methanol-water as the mobile phase with gradient elution.The detection was made on a diode array detector at 220 nm.Dichloromethane was selected as eluting solvent.The results indicated that the good linear ranges were 0.200 mg/L~5.00 mg/L for carbofuran,and 0.020 mg/L~5.00 mg/L for carbaryl and atrazine.The detection limits of the method were 0.24 μg/L,0.019 μg/L and 0.035 μg/L for carbofuran,carbaryl and atrazine,respectively.The average recoveries of spiked standard materials at two quantity levels were from 84.0 % to 103%,and RSD was from 1.6% to 8.5%.

Key concepts: Carbaryl, Carbofuran, Atrazine, Chromatography, Chemistry, High-performance liquid chromatography, Solid phase extraction, Elution

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Carbofuran,Carbaryl and Atrazine in Water by SPE-HPLC — Research Paper | ScholarLens