2001Journal of Analytical ScienceRequires access

A Kinetic Spectrophotometric Method for the Determination of Trace Chromium(VI) with Butylrhodamine B and Potassium Bromate

Zhao Xiao

Open publisher page 1 citations

Abstract

A new kinetic method for the determination of trace chromium(Ⅵ) was established based on the catalytic action of Cr(Ⅵ) on the oxidative fading reaction between butylrhodamine B and KBrO 3 in sulfuric acid mediun. The calibration graph was linear in the range of 0.040~2.0 μg/mL for Cr(Ⅵ), and the detection limit was 9.68×10 -10 g/mL. The method has been used for the determination of trace chromium in the eletroplating waste water with a satisfactory result.

About this research paper

What this paper is about

A new kinetic method for the determination of trace chromium(Ⅵ) was established based on the catalytic action of Cr(Ⅵ) on the oxidative fading reaction between butylrhodamine B and KBrO 3 in sulfuric acid mediun. The calibration graph was linear in the range of 0.040~2.0 μg/mL for Cr(Ⅵ), and the detection limit was 9.68×10 -10 g/mL. The method has been used for the determination of trace chromium in the eletroplating waste water with a satisfactory result.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new kinetic method for the determination of trace chromium(Ⅵ) was established based on the catalytic action of Cr(Ⅵ) on the oxidative fading reaction between butylrhodamine B and KBrO 3 in sulfuric acid mediun. The calibration graph was linear in the range of 0.040~2.0 μg/mL for Cr(Ⅵ), and the detection limit was 9.68×10 -10 g/mL. The method has been used for the determination of trace chromium in the eletroplating waste water with a satisfactory result.

Key concepts: Chemistry, Potassium bromate, Chromium, Detection limit, Bromate, Sulfuric acid, Linear range, Calibration curve

Related papers

Back to paper searchBrowse research topicsOriginal source
A Kinetic Spectrophotometric Method for the Determination of Trace Chromium(VI) with Butylrhodamine B and Potassium Bromate — Research Paper | ScholarLens