2007Zhongguo yaofangRequires access

Determination of Harpagosicle in Junduqing Granule by RP-HPLC Method

Zhong Zhao-jian, Xiao Ruo-mei

Open publisher page 0 citations

Abstract

OBJECTIVE:To develop a RP-HPLC method for the determination of Harpagosicle in Junduqing granule.METHODS:The chromatographic column was Diamonsil-C18(250mm× 4.6mm,5μ m) at room temperature.The mobile phase was acetonitrile-1% HAc(gradient elution).The flow rate was 1.0mL· min-1 and the detection wavelength was 278 nm.RESULTS:The linear range of Harpagosicle was 2.55~ 20.4μg· mL-1,with average recovery at 96.6%,RSD=0.67%(n=6).CONCLUSION:The method was proved to be sensitive and accurate,and it can be used as quality control of Junduqing granule.

About this research paper

What this paper is about

OBJECTIVE:To develop a RP-HPLC method for the determination of Harpagosicle in Junduqing granule.METHODS:The chromatographic column was Diamonsil-C18(250mm× 4.6mm,5μ m) at room temperature.The mobile phase was acetonitrile-1% HAc(gradient elution).The flow rate was 1.0mL· min-1 and the detection wavelength was 278 nm.RESULTS:The linear range of Harpagosicle was 2.55~ 20.4μg· mL-1,with average recovery at 96.6%,RSD=0.67%(n=6).CONCLUSION:The method was proved to be sensitive and accurate,and it can be used as quality control of Junduqing granule.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE:To develop a RP-HPLC method for the determination of Harpagosicle in Junduqing granule.METHODS:The chromatographic column was Diamonsil-C18(250mm× 4.6mm,5μ m) at room temperature.The mobile phase was acetonitrile-1% HAc(gradient elution).The flow rate was 1.0mL· min-1 and the detection wavelength was 278 nm.RESULTS:The linear range of Harpagosicle was 2.55~ 20.4μg· mL-1,with average recovery at 96.6%,RSD=0.67%(n=6).CONCLUSION:The method was proved to be sensitive and accurate,and it can be used as quality control of Junduqing granule.

Key concepts: Chromatography, Granule (geology), Chemistry, Gradient elution, High-performance liquid chromatography, Linear range, Linear relationship, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Harpagosicle in Junduqing Granule by RP-HPLC Method — Research Paper | ScholarLens