2011Chinese Journal of Health Laboratory TechnologyRequires access

Detemination of beryllium in the air of workplace by ICP-MS

DU Er-qing

Open publisher page 0 citations

Abstract

Objective:An ICP-MS method for the determination of Beryllium in the air of workplace was developed.Methods:Filter Membrane was digested in nitric acid and the content of beryllium was determined by ICP-MS.The linear correlation coefficient,the detection limit,the precision and the recovery were stuidied.Results:In 0 μg/L~50 μg/L range the linear correlation coefficient was 1.0000,the detection limit was 0.0096 μg/L,the RSD was1.7% and the recovery of the direct dilution method was 99.0%~101%.Conclusion:Determination of Beryllium in the air of workplace by ICP-MS was an effective method for its high sensitivity,fine reproducibility,rapidity and accuracy.

About this research paper

What this paper is about

Objective:An ICP-MS method for the determination of Beryllium in the air of workplace was developed.Methods:Filter Membrane was digested in nitric acid and the content of beryllium was determined by ICP-MS.The linear correlation coefficient,the detection limit,the precision and the recovery were stuidied.Results:In 0 μg/L~50 μg/L range the linear correlation coefficient was 1.0000,the detection limit was 0.0096 μg/L,the RSD was1.7% and the recovery of the direct dilution method was 99.0%~101%.Conclusion:Determination of Beryllium in the air of workplace by ICP-MS was an effective method for its high sensitivity,fine reproducibility,rapidity and accuracy.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:An ICP-MS method for the determination of Beryllium in the air of workplace was developed.Methods:Filter Membrane was digested in nitric acid and the content of beryllium was determined by ICP-MS.The linear correlation coefficient,the detection limit,the precision and the recovery were stuidied.Results:In 0 μg/L~50 μg/L range the linear correlation coefficient was 1.0000,the detection limit was 0.0096 μg/L,the RSD was1.7% and the recovery of the direct dilution method was 99.0%~101%.Conclusion:Determination of Beryllium in the air of workplace by ICP-MS was an effective method for its high sensitivity,fine reproducibility,rapidity and accuracy.

Key concepts: Beryllium, Detection limit, Correlation coefficient, Linear range, Linear correlation, Nitric acid, Chemistry, Dilution