2013Zhiye yu jiankangRequires access

A comparative study of ICP-MS and spectrophotometry in determination of tin dioxide in workplace air

Hou Tao-qiao

Open publisher page 0 citations

Abstract

[Objective]To compare the advantages and disadvantages between inductively coupled plasma mass spectrometry(ICP-MS) and quercetin spectrophotometry in determination of tin dioxide in workplace air.[Methods]Two methods were compared in the pretreatment method,linearity range,detection limit,precision,accuracy,determination of actual samples.[Results] For the spectrophotometry,the pretreatment time was 4-5 hours,the linearity range was 150-3 000 μg/L,the detection limit was 150 μg/L,the precision was 0.4%-1.1%,and the accuracy was 95%-97%.For ICP-MS method,the pretreatment time was 0.5 ~ 1.0 hour,the linearity range was 1-100 μg/L,the detection limit was 0.10 μg/L,the precision was 0.6%-1.4%,and the accuracy was 99%.Both two methods can effectively determine the concentration of tin dioxide in workplace air.[Conclusion] Compared with the quercetin spectrophotometry,ICP-MS method can greatly shorten the pretreatment time,has lower linearity range and detection limit,has the same precision and accuracy,and is suitable for low concentration samples,which can greatly improve the efficiency and quality of detection work.

About this research paper

What this paper is about

[Objective]To compare the advantages and disadvantages between inductively coupled plasma mass spectrometry(ICP-MS) and quercetin spectrophotometry in determination of tin dioxide in workplace air.[Methods]Two methods were compared in the pretreatment method,linearity range,detection limit,precision,accuracy,determination of actual samples.[Results] For the spectrophotometry,the pretreatment time was 4-5 hours,the linearity range was 150-3 000 μg/L,the detection limit was 150 μg/L,the precision was 0.4%-1.1%,and the accuracy was 95%-97%.For ICP-MS method,the pretreatment time was 0.5 ~ 1.0 hour,the linearity range was 1-100 μg/L,the detection limit was 0.10 μg/L,the precision was 0.6%-1.4%,and the accuracy was 99%.Both two methods can effectively determine the concentration of tin dioxide in workplace air.[Conclusion] Compared with the quercetin spectrophotometry,ICP-MS method can greatly shorten the pretreatment time,has lower linearity range and detection limit,has the same precision and accuracy,and is suitable for low concentration samples,which can greatly improve the efficiency and quality of detection work.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective]To compare the advantages and disadvantages between inductively coupled plasma mass spectrometry(ICP-MS) and quercetin spectrophotometry in determination of tin dioxide in workplace air.[Methods]Two methods were compared in the pretreatment method,linearity range,detection limit,precision,accuracy,determination of actual samples.[Results] For the spectrophotometry,the pretreatment time was 4-5 hours,the linearity range was 150-3 000 μg/L,the detection limit was 150 μg/L,the precision was 0.4%-1.1%,and the accuracy was 95%-97%.For ICP-MS method,the pretreatment time was 0.5 ~ 1.0 hour,the linearity range was 1-100 μg/L,the detection limit was 0.10 μg/L,the precision was 0.6%-1.4%,and the accuracy was 99%.Both two methods can effectively determine the concentration of tin dioxide in workplace air.[Conclusion] Compared with the quercetin spectrophotometry,ICP-MS method can greatly shorten the pretreatment time,has lower linearity range and detection limit,has the same precision and accuracy,and is suitable for low concentration samples,which can greatly improve the efficiency and quality of detection work.

Key concepts: Detection limit, Spectrophotometry, Linearity, Chemistry, Accuracy and precision, Chromatography, Analytical Chemistry (journal), Tin dioxide

Related papers

Back to paper searchBrowse research topicsOriginal source
A comparative study of ICP-MS and spectrophotometry in determination of tin dioxide in workplace air — Research Paper | ScholarLens