[Analysis of intraocular pressure and corneal thickness after laser in situ keratomileusis].

Pan Y, Y Zhang, Jinjiao Lian, K Wang

Open publisher page 5 citations

Abstract

OBJECTIVE: To analyze the changes and relationship of the intraocular pressure (IOP) and the corneal thickness (CT) after laser in situ keratomileusis (LASIK). METHODS: This prospective study comprised two groups: noncontact tonometer group 221 eyes (156 patients) 1 month after LASIK and 72 eyes (50 patients) 3 months after LASIK; Goldmann applanation tonometer group 60 eyes (36 patients) 1 month after LASIK. The spherical equivalent, the corneal thickness and the IOP readings were measured pre- and post-LASIK. RESULTS: The CT was thicker than the predicted value and it was much more prominent in the higher myopic group with more regression degree of refraction. The CT at postoperative 3 month was thicker than that at 1 month. There was a statistical decrease in mean tonometer readings, both with non-contact tonometer and Goldmann applanation tonometer; and there was statistically significant correlation between the changes of central corneal thickness and the changes of non-contact tonometer readings (r = 0.2, P < 0.002). The IOP decrease with Goldmann applanation tonometer was less than that with noncontact tonometer. CONCLUSIONS: The actual ablation depth of cornea is lower than the predicted. The IOP readings of the patients after LASIK are lower than the real IOP values. Further efforts should be made to improve the accuracy. Goldmann applanation tonometer is a better choice measuring IOP after excimer photoablative corneal refractive surgery.

About this research paper

What this paper is about

OBJECTIVE: To analyze the changes and relationship of the intraocular pressure (IOP) and the corneal thickness (CT) after laser in situ keratomileusis (LASIK). METHODS: This prospective study comprised two groups: noncontact tonometer group 221 eyes (156 patients) 1 month after LASIK and 72 eyes (50 patients) 3 months after LASIK; Goldmann applanation tonometer group 60 eyes (36 patients) 1 month after LASIK. The spherical equivalent, the corneal thickness and the IOP readings were measured pre- and post-LASIK. RESULTS: The CT was thicker than the predicted value and it was much more prominent in the higher myopic group with more regression degree of refraction. The CT at postoperative 3 month was thicker than that at 1 month. There was a statistical decrease in mean tonometer readings, both with non-contact tonometer and Goldmann applanation tonometer; and there was statistically significant correlation between the changes of central corneal thickness and the changes of non-contact tonometer readings (r = 0.2, P < 0.002). The IOP decrease with Goldmann applanation tonometer was less than that with noncontact tonometer. CONCLUSIONS: The actual ablation depth of cornea is lower than the predicted. The IOP readings of the patients after LASIK are lower than the real IOP values. Further efforts should be made to improve the accuracy. Goldmann applanation tonometer is a better choice measuring IOP after excimer photoablative corneal refractive surgery.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To analyze the changes and relationship of the intraocular pressure (IOP) and the corneal thickness (CT) after laser in situ keratomileusis (LASIK). METHODS: This prospective study comprised two groups: noncontact tonometer group 221 eyes (156 patients) 1 month after LASIK and 72 eyes (50 patients) 3 months after LASIK; Goldmann applanation tonometer group 60 eyes (36 patients) 1 month after LASIK. The spherical equivalent, the corneal thickness and the IOP readings were measured pre- and post-LASIK. RESULTS: The CT was thicker than the predicted value and it was much more prominent in the higher myopic group with more regression degree of refraction. The CT at postoperative 3 month was thicker than that at 1 month. There was a statistical decrease in mean tonometer readings, both with non-contact tonometer and Goldmann applanation tonometer; and there was statistically significant correlation between the changes of central corneal thickness and the changes of non-contact tonometer readings (r = 0.2, P < 0.002). The IOP decrease with Goldmann applanation tonometer was less than that with noncontact tonometer. CONCLUSIONS: The actual ablation depth of cornea is lower than the predicted. The IOP readings of the patients after LASIK are lower than the real IOP values. Further efforts should be made to improve the accuracy. Goldmann applanation tonometer is a better choice measuring IOP after excimer photoablative corneal refractive surgery.

Key concepts: LASIK, Keratomileusis, Goldmann Applanation Tonometer, Ophthalmology, Intraocular pressure, Medicine, Cornea, Applanation tonometry

Related papers

Back to paper searchBrowse research topicsOriginal source
[Analysis of intraocular pressure and corneal thickness after laser in situ keratomileusis]. — Research Paper | ScholarLens