2002Journal of GlaucomaRequires access

Effect of Mild to Moderate Myopic Correction by Laser-Assisted In Situ Keratomileusis on Intraocular Pressure Measurements with Goldmann Applanation Tonometer, Tono-Pen, and Pneumatonometer

Roya Vakili, Saira A. Choudhri, Shachar Tauber, M. Bruce Shields

Open publisher page 28 citations

Abstract

PURPOSE: To evaluate the effect of mild to moderate myopic correction by laser-assisted in situ keratomileusis (LASIK) on intraocular pressure (IOP) measurements with three tonometers: the Goldmann applanation tonometer, Tono-Pen, and pneumatonometer. PATIENTS AND METHODS: In a prospective study of a clinic-based population undergoing elective LASIK surgery for myopia correction, IOP measurements were obtained preoperatively and postoperatively with a Goldmann applanation tonometer, Tono-Pen, and pneumatonometer. Central corneal thickness and keratometric and astigmatism measurements were also obtained before and after surgery. A paired test was used to evaluate the significance of differences between preoperative and postoperative IOP measurements with each instrument. Linear regression was used to correlate IOP measurements with degree of myopia corrected, astigmatism, and central corneal thickness before and after surgery. RESULTS: The study included 66 eyes of 34 individuals with a mean preoperative refractive error of -5.66 + 2.3 D (mean + SD). The reduction of central corneal thickness after LASIK of 0.032 + 0.030 mm (mean + SD) was statistically significant ( < 0.0001). However, there was no statistically significant change in mean IOP after the procedure with the Goldmann applanation tonometer or the Tono-Pen, while the pneumatonometer, was associated with a small but statistically significant decrease in mean IOP of 1.1 mm Hg. CONCLUSION: In this group of patients with mild to moderate myopia, LASIK had little or no statistically significant influence on IOP readings obtained with a Goldmann applanation tonometer, Tono-Pen, or pneumatonometer. This finding is in contrast to earlier reports of greater amounts of myopic correction, in which significant reductions in measured IOP were observed. Further study is needed to determine whether a critical amount of corneal change after LASIK is required to have a significant effect on IOP measurements.

About this research paper

What this paper is about

PURPOSE: To evaluate the effect of mild to moderate myopic correction by laser-assisted in situ keratomileusis (LASIK) on intraocular pressure (IOP) measurements with three tonometers: the Goldmann applanation tonometer, Tono-Pen, and pneumatonometer. PATIENTS AND METHODS: In a prospective study of a clinic-based population undergoing elective LASIK surgery for myopia correction, IOP measurements were obtained preoperatively and postoperatively with a Goldmann applanation tonometer, Tono-Pen, and pneumatonometer. Central corneal thickness and keratometric and astigmatism measurements were also obtained before and after surgery. A paired test was used to evaluate the significance of differences between preoperative and postoperative IOP measurements with each instrument. Linear regression was used to correlate IOP measurements with degree of myopia corrected, astigmatism, and central corneal thickness before and after surgery. RESULTS: The study included 66 eyes of 34 individuals with a mean preoperative refractive error of -5.66 + 2.3 D (mean + SD). The reduction of central corneal thickness after LASIK of 0.032 + 0.030 mm (mean + SD) was statistically significant ( < 0.0001). However, there was no statistically significant change in mean IOP after the procedure with the Goldmann applanation tonometer or the Tono-Pen, while the pneumatonometer, was associated with a small but statistically significant decrease in mean IOP of 1.1 mm Hg. CONCLUSION: In this group of patients with mild to moderate myopia, LASIK had little or no statistically significant influence on IOP readings obtained with a Goldmann applanation tonometer, Tono-Pen, or pneumatonometer. This finding is in contrast to earlier reports of greater amounts of myopic correction, in which significant reductions in measured IOP were observed. Further study is needed to determine whether a critical amount of corneal change after LASIK is required to have a significant effect on IOP measurements.

Why it matters

OpenAlex reports 28 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To evaluate the effect of mild to moderate myopic correction by laser-assisted in situ keratomileusis (LASIK) on intraocular pressure (IOP) measurements with three tonometers: the Goldmann applanation tonometer, Tono-Pen, and pneumatonometer. PATIENTS AND METHODS: In a prospective study of a clinic-based population undergoing elective LASIK surgery for myopia correction, IOP measurements were obtained preoperatively and postoperatively with a Goldmann applanation tonometer, Tono-Pen, and pneumatonometer. Central corneal thickness and keratometric and astigmatism measurements were also obtained before and after surgery. A paired test was used to evaluate the significance of differences between preoperative and postoperative IOP measurements with each instrument. Linear regression was used to correlate IOP measurements with degree of myopia corrected, astigmatism, and central corneal thickness before and after surgery. RESULTS: The study included 66 eyes of 34 individuals with a mean preoperative refractive error of -5.66 + 2.3 D (mean + SD). The reduction of central corneal thickness after LASIK of 0.032 + 0.030 mm (mean + SD) was statistically significant ( < 0.0001). However, there was no statistically significant change in mean IOP after the procedure with the Goldmann applanation tonometer or the Tono-Pen, while the pneumatonometer, was associated with a small but statistically significant decrease in mean IOP of 1.1 mm Hg. CONCLUSION: In this group of patients with mild to moderate myopia, LASIK had little or no statistically significant influence on IOP readings obtained with a Goldmann applanation tonometer, Tono-Pen, or pneumatonometer. This finding is in contrast to earlier reports of greater amounts of myopic correction, in which significant reductions in measured IOP were observed. Further study is needed to determine whether a critical amount of corneal change after LASIK is required to have a significant effect on IOP measurements.

Key concepts: Medicine, Keratomileusis, LASIK, Goldmann Applanation Tonometer, Intraocular pressure, Ophthalmology, Glaucoma, Applanation tonometry

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of Mild to Moderate Myopic Correction by Laser-Assisted In Situ Keratomileusis on Intraocular Pressure Measurements with Goldmann Applanation Tonometer, Tono-Pen, and Pneumatonometer — Research Paper | ScholarLens