2008Zhongguo shiyan fangjixue zazhiRequires access

Determination of Ursolic Acid in Hawthorn Leaves by HPLC

LU Wen-sheng

Open publisher page 2 citations

Abstract

Objective:To develop an HPLC method for determination of ursolic acid in Hawthorn Leaves. Methods:The C_ 18 column with methanol-water-phosphorous acid (90∶10∶0.03) as the mobile phase was used. The flow rate was 0.5 mL·min~ -1 and the detection wavelength was 220 nm. Results:The linear range of calibration curve was (0.982~9.82) μg·mL~ -1 for ursolic acid (r= 0.999 8 ). The average recovery was 98.16% and the RSD was 0.58% (n=6). Conclusion:The method is simple, accurate and repeatable. It can be used for the quality control of Hawthorn Leaves.

About this research paper

What this paper is about

Objective:To develop an HPLC method for determination of ursolic acid in Hawthorn Leaves. Methods:The C_ 18 column with methanol-water-phosphorous acid (90∶10∶0.03) as the mobile phase was used. The flow rate was 0.5 mL·min~ -1 and the detection wavelength was 220 nm. Results:The linear range of calibration curve was (0.982~9.82) μg·mL~ -1 for ursolic acid (r= 0.999 8 ). The average recovery was 98.16% and the RSD was 0.58% (n=6). Conclusion:The method is simple, accurate and repeatable. It can be used for the quality control of Hawthorn Leaves.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To develop an HPLC method for determination of ursolic acid in Hawthorn Leaves. Methods:The C_ 18 column with methanol-water-phosphorous acid (90∶10∶0.03) as the mobile phase was used. The flow rate was 0.5 mL·min~ -1 and the detection wavelength was 220 nm. Results:The linear range of calibration curve was (0.982~9.82) μg·mL~ -1 for ursolic acid (r= 0.999 8 ). The average recovery was 98.16% and the RSD was 0.58% (n=6). Conclusion:The method is simple, accurate and repeatable. It can be used for the quality control of Hawthorn Leaves.

Key concepts: Ursolic acid, Chromatography, Calibration curve, High-performance liquid chromatography, Chemistry, Recovery rate, Linear relationship, Methanol

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Ursolic Acid in Hawthorn Leaves by HPLC — Research Paper | ScholarLens