2007•PubMedRequires access

[Determination of macrozamin in Rhizoma Heterosmilacis Japonicae by RP-HPLC].

Lei Qiao, Xiao-Hui Chen, Kaishun Bi

Open publisher page 1 citations

Abstract

OBJECTIVE: To develop a RP-HPLC method for the determination of the content of macrozamin in Rhizoma Heterosmilacis Japonicae. METHOD: A Century C18 AQ column (4.6 mm x 250 mm, 5 microm) was used with the mobile phase consisted of water (4:96). The flow rate was 1.0 mL x min(-1). The detection wavelength was set at 215 nm, and the column temperature was 35 degrees C. RESULT: The calibration curve was linear (r = 0.999 8) in the range of 19.12 - 382.4 microg x mL(-1) for macrozamin, the average recovery of the method was 99.5%, with RSD 2.1% (n = 9). CONCLUSION: This method can be used for the quality study of Rhizoma Heterosmilacis Japonicae.

About this research paper

What this paper is about

OBJECTIVE: To develop a RP-HPLC method for the determination of the content of macrozamin in Rhizoma Heterosmilacis Japonicae. METHOD: A Century C18 AQ column (4.6 mm x 250 mm, 5 microm) was used with the mobile phase consisted of water (4:96). The flow rate was 1.0 mL x min(-1). The detection wavelength was set at 215 nm, and the column temperature was 35 degrees C. RESULT: The calibration curve was linear (r = 0.999 8) in the range of 19.12 - 382.4 microg x mL(-1) for macrozamin, the average recovery of the method was 99.5%, with RSD 2.1% (n = 9). CONCLUSION: This method can be used for the quality study of Rhizoma Heterosmilacis Japonicae.

Why it matters

OpenAlex reports 1 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To develop a RP-HPLC method for the determination of the content of macrozamin in Rhizoma Heterosmilacis Japonicae. METHOD: A Century C18 AQ column (4.6 mm x 250 mm, 5 microm) was used with the mobile phase consisted of water (4:96). The flow rate was 1.0 mL x min(-1). The detection wavelength was set at 215 nm, and the column temperature was 35 degrees C. RESULT: The calibration curve was linear (r = 0.999 8) in the range of 19.12 - 382.4 microg x mL(-1) for macrozamin, the average recovery of the method was 99.5%, with RSD 2.1% (n = 9). CONCLUSION: This method can be used for the quality study of Rhizoma Heterosmilacis Japonicae.

Key concepts: Chromatography, Calibration curve, High-performance liquid chromatography, Content determination, Chemistry, Linear range, Analytical Chemistry (journal), Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of macrozamin in Rhizoma Heterosmilacis Japonicae by RP-HPLC]. — Research Paper | ScholarLens