2009Physical Testing and Chemical AnalysisRequires access

Simultaneous ICP-AES Determination of Iron Manganese Copper Zinc in Tremella with Microwave Assisted Sample Digestion

Tang Jiao-rong

Open publisher page 0 citations

Abstract

The tremella sample was digested with mixed solution of HNO3-H2O2(7+2) by microwave sample digestion system and the contents of Fe,Mn,Cu,Zn in sample solution were determined by ICP-AES.Wavelengths of 238.204,257.610,324.752 and 206.200 nm were selected as analytical spectral lines for determination of Fe,Mn,Cu and Zn respectively.Values of RSD′s(n=5) of Fe,Mn,Cu and Zn were in the range of 1.4%-2.3%,and detection limits(3s) found were less than 0.015 mg·L-1.The proposed method was used in the determination of the 4 elements in tremella,giving values of recovery in the range of 89.6%-97.3%.The results obtained was in conformity with those obtained by AAS.

About this research paper

What this paper is about

The tremella sample was digested with mixed solution of HNO3-H2O2(7+2) by microwave sample digestion system and the contents of Fe,Mn,Cu,Zn in sample solution were determined by ICP-AES.Wavelengths of 238.204,257.610,324.752 and 206.200 nm were selected as analytical spectral lines for determination of Fe,Mn,Cu and Zn respectively.Values of RSD′s(n=5) of Fe,Mn,Cu and Zn were in the range of 1.4%-2.3%,and detection limits(3s) found were less than 0.015 mg·L-1.The proposed method was used in the determination of the 4 elements in tremella,giving values of recovery in the range of 89.6%-97.3%.The results obtained was in conformity with those obtained by AAS.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The tremella sample was digested with mixed solution of HNO3-H2O2(7+2) by microwave sample digestion system and the contents of Fe,Mn,Cu,Zn in sample solution were determined by ICP-AES.Wavelengths of 238.204,257.610,324.752 and 206.200 nm were selected as analytical spectral lines for determination of Fe,Mn,Cu and Zn respectively.Values of RSD′s(n=5) of Fe,Mn,Cu and Zn were in the range of 1.4%-2.3%,and detection limits(3s) found were less than 0.015 mg·L-1.The proposed method was used in the determination of the 4 elements in tremella,giving values of recovery in the range of 89.6%-97.3%.The results obtained was in conformity with those obtained by AAS.

Key concepts: Inductively coupled plasma atomic emission spectroscopy, Zinc, Copper, Manganese, Analytical Chemistry (journal), Chemistry, Microwave digestion, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous ICP-AES Determination of Iron Manganese Copper Zinc in Tremella with Microwave Assisted Sample Digestion — Research Paper | ScholarLens